Point-of-Care Quantification of Serum Alpha-Fetoprotein for Screening Birth Defects in Resource-Limited Settings: Proof-of-Concept Study

Author:

Srinivasan BalajiORCID,Finkelstein Julia LORCID,Erickson DavidORCID,Mehta SaurabhORCID

Abstract

Background Maternal serum alpha-fetoprotein (MSAFP) concentration typically increases during pregnancy and is routinely measured during the second trimester as a part of screening for fetal neural tube defects and Down syndrome. However, most pregnancy screening tests are not available in the settings they are needed the most. A mobile device–enabled technology based on MSAFP for screening birth defects could enable the rapid screening and triage of high-risk pregnancies, especially where maternal serum screening and fetal ultrasound scan facilities are not easily accessible. Shifting the approach from clinic- and laboratory-dependent care to a mobile platform based on our point-of-care approach will enable translation to resource-limited settings and the global health care market. Objective The objective of this study is to develop and perform proof-of-concept testing of a lateral flow immunoassay on a mobile platform for rapid, point-of-care quantification of serum alpha-fetoprotein (AFP) levels, from a drop of human serum, within a few minutes. Methods The development of the immunoassay involved the selection of commercially available antibodies and optimization of their concentrations by an iterative method to achieve the required detection limits. We compared the performance of our method with that of commercially obtained human serum samples, with known AFP concentrations quantified by the Abbott ARCHITECT chemiluminescent magnetic microparticle immunoassay (CMIA). Results We tested commercially obtained serum samples (N=20) with concentrations ranging from 2.2 to 446 ng/mL to compare the results of our point-of-care assay with results from the Abbott ARCHITECT CMIA. A correlation of 0.98 (P<.001) was observed on preliminary testing and comparison with the CMIA. The detection range of our point-of-care assay covers the range of maternal serum AFP levels observed during pregnancy. Conclusions The preliminary test results from the AFP test on the mobile platform performed in this study represent a proof of concept that will pave the way for our future work focused on developing a mobile device–enabled quad-screen point-of-care testing with the potential to enable the screening of high-risk pregnancies in various settings. The AFP test on the mobile platform can be applied to enable screening for high-risk pregnancies, within a few minutes, at the point of care even in remote areas where maternal serum tests and fetal ultrasound scans are not easily accessible; assessment of whether clinical follow-up and diagnostic testing may be needed after a positive initial screening evaluation; and development of surveillance tools for birth defects.

Publisher

JMIR Publications Inc.

Subject

General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3