Heart Rate Monitoring Among Breast Cancer Survivors: Quantitative Study of Device Agreement in a Community-Based Exercise Program

Author:

Page Lindsey LORCID,Fanning JasonORCID,Phipps ConnorORCID,Berger AnnORCID,Reed ElizabethORCID,Ehlers DianeORCID

Abstract

Background Exercise intensity (eg, target heart rate [HR]) is a fundamental component of exercise prescription to elicit health benefits in cancer survivors. Despite the validity of chest-worn monitors, their feasibility in community and unsupervised exercise settings may be challenging. As wearable technology continues to improve, consumer-based wearable sensors may represent an accessible alternative to traditional monitoring, offering additional advantages. Objective The purpose of this study was to examine the agreement between the Polar H10 chest monitor and Fitbit Inspire HR for HR measurement in breast cancer survivors enrolled in the intervention arm of a randomized, pilot exercise trial. Methods Participants included breast cancer survivors (N=14; aged 38-72 years) randomized to a 12-week aerobic exercise program. This program consisted of three 60-minute, moderate-intensity walking sessions per week, either in small groups or one-on-one, facilitated by a certified exercise physiologist and held at local community fitness centers. As originally designed, the exercise prescription included 36 supervised sessions at a fitness center. However, due to the COVID-19 pandemic, the number of supervised sessions varied depending on whether participants enrolled before or after March 2020. During each exercise session, HR (in beats per minute) was concurrently measured via a Polar H10 chest monitor and a wrist-worn Fitbit Inspire HR at 5 stages: pre-exercise rest; midpoint of warm-up; midpoint of exercise session; midpoint of cool-down; and postexercise recovery. The exercise physiologist recorded the participant’s HR from each device at the midpoint of each stage. HR agreement between the Polar H10 and Fitbit Inspire HR was assessed using Lin concordance correlation coefficient (rc) with a 95% CI. Lin rc ranges from 0 to 1.00, with 0 indicating no concordance and 1.00 indicating perfect concordance. Relative error rates were calculated to examine differences across exercise session stages. Results Data were available for 200 supervised sessions across the sample (session per participant: mean 13.33, SD 13.7). By exercise session stage, agreement between the Polar H10 monitor and the Fitbit was highest during pre-exercise seated rest (rc=0.76, 95% CI 0.70-0.81) and postexercise seated recovery (rc=0.89, 95% CI 0.86-0.92), followed by the midpoint of exercise (rc=0.63, 95% CI 0.55-0.70) and cool-down (rc=0.68, 95% CI 0.60-0.74). The agreement was lowest during warm-up (rc=0.39, 95% CI 0.27-0.49). Relative error rates ranged from –3.91% to 3.09% and were greatest during warm-up (relative error rate: mean –3.91, SD 11.92%). Conclusions The Fitbit overestimated HR during peak exercise intensity, posing risks for overexercising, which may not be safe for breast cancer survivors’ fitness levels. While the Fitbit Inspire HR may be used to estimate exercise HR, precautions are needed when considering participant safety and data interpretation. Trial Registration Clinicaltrials.gov NCT03980626; https://clinicaltrials.gov/study/NCT03980626?term=NCT03980626&rank=1

Publisher

JMIR Publications Inc.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3