Development of a Connected Sensor System in Colorectal Surgery: User-Centered Design Case Study

Author:

Schwartz-Lasfargues ChristelORCID,Roux-Gendron CamilleORCID,Edomskis PimORCID,Marque IsabelleORCID,Bayon YvesORCID,Lange Johan FORCID,Faucheron Jean LucORCID,Trilling BertrandORCID

Abstract

Background A successful innovative medical device is not only technically challenging to develop but must also be readily usable to be integrated into health care professionals’ daily practice. Through a user-centered design (UCD) approach, usability can be improved. However, this type of approach is not widely implemented from the early stages of medical device development. Objective The case study presented here shows how UCD may be applied at the very early stage of the design of a disruptive medical device used in a complex hospital environment, while no functional device is available yet. The device under study is a connected sensor system to detect colorectal anastomotic leakage, the most detrimental complication following colorectal surgery, which has a high medical cost. We also aimed to provide usability guidelines for the initial design of other innovative medical devices. Methods UCD was implemented by actively involving health care professionals and all the industrial partners of the project. The methodology was conducted in 2 European hospitals: Grenoble-Alpes University Hospital (France) and Erasmus Medical Center Rotterdam (the Netherlands). A total of 6 elective colorectal procedures and 5 ward shifts were observed. In total, 4 workshops were conducted with project partners and clinicians. A formative evaluation was performed based on 5 usability tests using nonfunctional prototype systems. The case study was completed within 12 months. Results Functional specifications were defined for the various components of the medical device: device weight, size, design, device attachment, and display module. These specifications consider the future integration of the medical device into current clinical practice (for use in an operating room and patient follow-up inside the hospital) and interactions between surgeons, nurses, nurse assistants, and patients. By avoiding irrelevant technical development, this approach helps to promote cost-effective design. Conclusions This paper presents the successful deployment over 12 months of a UCD methodology for the design of an innovative medical device during its early development phase. To help in reusing this methodology to design other innovative medical devices, we suggested best practices based on this case.

Publisher

JMIR Publications Inc.

Subject

Health Informatics,Human Factors and Ergonomics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3