Seismic Response of Slab Column Connection with Pyramid Shaped Drop Panel

Author:

Ibrahim Ahmed, ,Elkader Dr. Hilal Abd,Husain Prof. Mohamed M., ,

Abstract

Both experimental and finite element analysis (FEA) was used to study the seismic response of reinforced concrete (RC) interior slab-column connection made with pyramid-shaped drop panel subjected to vertical and horizontal loads. The dimensions of the models at “¼ ” linear scale for laboratory testing and FE Analysis (FEA) are derived from rules for dimensions of column drops, given a prototype “9.60m” grid and a slab thickness of “320mm”. Lab specimens were tested with the drops (flat slab, rectangular and pyramid-shaped) facing up, with loadings (vertical down and horizontal in grid direction) applied by jacks towards the top of a central projecting “150mm” square column. One flat slab (“80mm” thick no drop), tested to failure under vertical load (80kN), provided values for setting variables used in the FEA. The remaining 5 lab specimens (1 flat and 1 each rectangular and pyramid-shaped 40mm and 30mm drop thicknesses), under a fixed vertical load (40kN), were tested to failure by increasing a moment at the column slab junction applied by a horizontal load to the column “500mm” above the slab. FEA results for the same conditions compared closely with experimental results. The pyramid-shaped drop models, with equal thickness to the rectangular drop models at the column faces (drops of “40mm” and “30mm”), exhibit similar maximum force resistances to the rectangular drop models. However, these resistances were achieved in the pyramid drops at higher maximum deflections – deflections being measured downwards at column centerline one half of slab thickness away from the face. A parametric study was conducted by FEA, at constant load, in vertical steps (10kN; 25kN 55kN), calculating deflections under increasing horizontal load. Calculations were made on the following definitions: Energy absorption is represented by the area under the deflection vs horizontal load curves; Ductility is the ratio of deflection at maximum to deflection at yield, and Stiffness and Overstrength factors are the slopes of the deflection load diagrams in the elastic and plastic zones respectively. Both drop type models exhibit significantly improved performance compared to the models without drops. The pyramid-shaped drop models exhibited improved energy absorption, ductility, and stiffness and overstrength compared to the rectangular drop models of the same column face thickness.

Publisher

Blue Eyes Intelligence Engineering and Sciences Engineering and Sciences Publication - BEIESP

Subject

Computer Science Applications,General Engineering,Environmental Engineering

Reference13 articles.

1. Alam, A.K.M. (1997). Punching Shear Behaviour of Reinforcement Concrete Slabs. M.Sc. Engineering Thesis.

2. ECP 203 (2018). The Egyptian Code for Design and Construction of Concrete Structures. Cairo: Egypt: Ministry of Housing.

3. Effects of Stud Rails on Resistance of Edge Slab-Column Connections. (2010). American Society of Civil Engineer 6th International Engineering & Construction Conference, pp.28-30. Cairo: Egypt.

4. Genikomsou, A.S. and Polak, M.A. (2015). Damaged Plasticity Modelling of Concrete in Finite Element Analysis of Reinforced Concrete Slabs. Waterloo, Canada. [CrossRef]

5. Graf, W.P. and Mehrain, M. (1992). Analysis and testing of a flat slab concrete building. Dames & Moore. Los Angeles, California: USA.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3