Author:
ELURU ASHA,BABU K. SURENDRA
Abstract
Objective: This investigation demonstrates a stability-indicating and reliable “reverse-phase ultra-performance liquid chromatography” method to simultaneously quantify timolol maleate and dorzolamide HCl in the pharmaceutical dosage form.
Methods: Successful separation was accomplished using Phenyl column (100 mm x 2.1 mm, 1.7μm) with isocratic type of elution using mobile phase containing Acetonitrile+Ammonium Formate buffer (30:70), respectively with 0.2 ml/min flow rate. The wavelength sensor was attuned at 266 nm to quantify timolol maleate and dorzolamide HCl.
Results: Dorzolamide HCl and timolol maleate peaks were eluted with fine resolution at retention times 0.7 min and 1.5 min, respectively. In the 55.75-334.5 μg/ml and 6.25-37.5 μg/ml concentration ranges for dorzolamide HCl and timolol maleate, the calibration graphs were linear, with regression coefficients of 0.99997 and 0.99991, respectively. The suggested ultra-performance liquid chromatography approach has been shown as sensitive, precise, robust, accurate, specific and stability, indicating through the resolution of dorzolamide HCl and timolol maleate from its degradation-based compounds.
Conclusion: The established ultra-performance liquid chromatography technique was effectively extended to the evaluation of dorzolamide HCl and timolol Maleate in the pharmaceutical dosage form and the test results appeared satisfactory.
Publisher
Innovare Academic Sciences Pvt Ltd