DETERMINATION OF TOXIC HEAVY METALS IN CHOLIC ACID USING QUADRUPOLE INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

Author:

Kumar Thakar Meet,Vaishali Suthar,Jateen Sheth,Pulidindi Indra Neel,PANKAJ SHARMAORCID

Abstract

Objective: The information on the presence of toxic heavy metals in pharmaceutical starting materials and finished product is very crucial from the viewpoint of human life and its hazardous impact on the worldwide environment. The present work deals with the detailed quantification of the toxic heavy metals, namely, V, Co, Ni, Cd, Hg, Pb, and As, present in colic acid using quadrupole inductively coupled plasma mass spectrometry (Q-ICPMS) with prior microwave-assisted digestion. Moreover, the preliminary characterization of commercially available cholic acid by FT-IR, NMR (1H and 13C), SEM-EDAX has also been carried out. Methods: Cholic acid of synthesis grade, Nitric acid (65%) AR. grade, ethylene diamine tetra acetic acid sodium salt AR grade, and certified reference metal stock standard solutions (1000 mg/L) of multiple elements prepared in 2–3% HNO3 of analytical grade were purchased from Merck (Darmstadt, Germany). All the samples were treated with nitric acid and microwave-assisted digestion. For the accurate determination of the elemental amount, various digested solutions and post-digestion diluents were tested. The linearity, accuracy, precision, limit of detection (LOD), and limit of quantification (LOQ) of the analytical technique were evaluated in accordance with the United States Pharmacopoeia 233 standard. Results and Discussion: The Q-ICPMS-based analytical method was validated for specificity, LOD, LOQ, linearity, accuracy, precision, and uncertainty. The estimated detection limits of the toxic heavy metals in cholic acid were in the range 2–180 μg/L. The quantification limits were in the range of 1.5–60 μg/L. Mean recoveries±standard deviations at different spiking levels were in the range 75.3±2.1–104.9±8.5%. The coefficients of variation were in the range of 0.5–8.1%. Conclusion: The precision of the analytical method, in terms of relative standard deviation, was below 1.95%. The uncertainty in the quantification of all the validated elements was found to be ≤1.70% for Sample 1.

Publisher

Innovare Academic Sciences Pvt Ltd

Subject

Pharmacology (medical),Pharmaceutical Science,Pharmacology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3