Characterization of Unbound Phenytoin Concentrations in Neurointensive Care Unit Patients Using a Revised Winter-Tozer Equation

Author:

Kane Sean P1,Bress Adam P2,Tesoro Eljim P3

Affiliation:

1. Sean P Kane PharmD BCPS, at time of study, PGY2 Critical Care Resident, Department of Pharmacy Practice, University of Illinois at Chicago; now, Assistant Professor, Critical Care Clinical Pharmacist, Department of Pharmacy Practice, Rosalind Franklin University of Medicine and Science, North Chicago, IL

2. Adam P Bress PharmD, Fellow, Department of Pharmacy Practice, University of Illinois at Chicago

3. Eljim P Tesoro PharmD BCPS, Clinical Associate Professor, Department of Pharmacy Practice, University of Illinois at Chicago

Abstract

BACKGROUND Prior studies examining the accuracy of the Winter-Tozer (WT) equation for correcting total phenytoin concentrations in critically ill patients have yielded conflicting results and are limited by small sample sizes and stringent exclusion criteria, which lessen external validity. OBJECTIVE To determine whether the traditional WT equation is appropriate in correcting total phenytoin concentrations in a large sample of patients in a neurointensive care unit (NICU) and whether a new equation may be more predictive. METHODS In a retrospective study, NICU patients with reports of a concurrent total and unbound phenytoin concentration and albumin level were analyzed. Two new predictive equations were generated using a revised WT equation and regression model of baseline and laboratory characteristics. Prediction error analysis using a 20% validation cohort was conducted on all 3 equations for comparison. RESULTS A total of 140 adults were included for data analysis, with data on 80% used for derivation and 20% as validation of all equations. The mean unbound phenytoin concentration was 1.4 μg/mL, which represented a free fraction of 10%. Most samples were collected within 24 hours of NICU admission. Multivariate regression analysis demonstrated that albumin, total phenytoin concentration, sex, and creatinine clearance were predictive of measured unbound phenytoin concentrations. The traditional WT equation significantly underpredicted true unbound phenytoin concentrations, with 32.1% of patients having a prediction error of more than 50% in the validation cohort. CONCLUSIONS The traditional WT equation was significantly biased in underpredicting true unbound phenytoin concentrations in neurointensive care unit patients and should not be used in this setting. Two modified equations were more accurate and precise and should be considered for use when unbound phenytoin concentrations are not readily available in an NICU population.

Publisher

SAGE Publications

Subject

Pharmacology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3