Accuracy of Measured Vancomycin Serum Concentrations in Patients with End-Stage Renal Disease

Author:

Smith Patrick F1,Morse Gene D2

Affiliation:

1. Patrick F Smith PharmD, Clinical Assistant Professor, Department of Pharmacy Practice, School of Pharmacy, State University of New York at Buffalo, Buffalo, NY

2. Gene D Morse PharmD FCCP, Professor, Department of Pharmacy Practice, School of Pharmacy, State University of New York at Buffalo

Abstract

OBJECTIVE: TO review information related to the accuracy of vancomycin serum drug concentrations in patients with end-stage renal disease, focusing on available assays and mechanisms of cross-reactivity. DATA SOURCES: Primary and review articles identified from a MEDLINE search (January 1980-June 1999) and through secondary sources. STUDY SELECTION AND DATA EXTRACTION: All articles identified were evaluated, and all relevant information was included in this review. DATA SYNTHESIS: Falsely elevated vancomycin serum concentrations may occur in patients with renal dysfunction. The underlying mechanism is due to the formation and accumulation of a pseudo-metabolite, the vancomycin crystalline degradation product (CDP). Vancomycin is converted to CDP when exposed to heat, including normal body temperature. Because the molecular structures of CDP and vancomycin are similar, both molecules are detected by polyclonal immunoassay systems used in clinical laboratories. This cross-reactivity leads to falsely elevated serum vancomycin concentrations in excess of 50–70%. Such large assay inaccuracies may result in improper dosage adjustments and therapeutic failures. A monoclonal immunoassay system has been developed that does not significantly cross-react with CDP. CONCLUSIONS: TO appropriately interpret laboratory results, it is essential for clinicians to be aware of the vancomycin-CDP cross-reactivity problem and to be familiar with the specific assay used to measure vancomycin concentrations in patients with renal dysfunction.

Publisher

SAGE Publications

Subject

Pharmacology (medical)

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3