Evaluation of Compliance with a Paper-based, Multiplication-factor, Intravenous Insulin Protocol

Author:

Cyrus Rachel M1,Szumita Paul M2,Greenwood Bonnie C2,Pendergrass Merri L3

Affiliation:

1. Department of Pharmacy, Pharmacy Administration; L-2, Brigham and Women's Hospital, Boston, MA

2. Department of Pharmacy, Pharmacy Administration; L-2, Brigham and Women's Hospital

3. Diabetes, Medco, Colleyville, TX

Abstract

Background:Hyperglycemia is common in critically ill patients and is an independent risk factor for in-hospital morbidity and mortality.Objective:To assess compliance with a paper-based, multiplication-factor, intravenous insulin protocol.Methods:A retrospective chart review was conducted in a 720-bed urban, academic medical center in Boston, Massachusetts. During a 1-month period, compliance with and the consequent safety and efficacy of the Brigham and Women's Hospital paper-based, multiplication-factor, intravenous insulin protocol was evaluated.Results:The primary endpoint of protocol compliance, defined as correct adjustment to insulin infusion rate and correct timing of bedside blood glucose concentration (BBGC) checks ±10 minutes of prespecified BBGC check according to the Brigham and Women's Hospital Intravenous Insulin Protocol (BHIP), was 47.2%. Seventy-two patients met inclusion criteria. Appropriate adjustment of infusion rates occurred 68.2% (1206/1768) of the time. Compliance with the timing of BBGC checks was found to be the majority of protocol violations. BBGCs were monitored ±5 minutes of indicated time per the protocol 26.2% (463/1768) of the time. Blood glucose concentration checks within extended timing of ±10 minutes of indicated time per the protocol occurred 793 (44.8%) times. Blood glucose concentration monitoring took place greater than 20 minutes past indicated time 450 (25.5%) times. In 1768 measurements, blood glucose concentrations between 40 and 60 mg/dL occurred 23 (1.3%) times in 12 (16.7%) patients. Blood glucose concentrations 40 mg/dL or less were detected 3 (0.17%) times in 2 (2.7%) patients. None of these hypoglycemic events led to documented complications.Conclusions:Overall, a rather low level of compliance with a paper-based, multiplication-factor, intravenous insulin protocol was observed, which warrants further investigation. Compliance rates in this evaluation were found to be similar to the rates observed in previously evaluated fixed-dose intravenous insulin protocols. Protocol noncompliance may be associated with hypo- and hyperglycemia.

Publisher

SAGE Publications

Subject

Pharmacology (medical)

Cited by 25 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3