Discordant Results from “Real-World” Patient Samples Assayed for Digoxin

Author:

Jones Terry E1,Morris Raymond G2

Affiliation:

1. Department of Pharmacy, The Queen Elizabeth Hospital, Woodville, South Australia

2. Department of Clinical Pharmacology, The Queen Elizabeth Hospital; Discipline of Pharmacology, University of Adelaide, Adelaide, South Australia

Abstract

Background: Digoxin has a narrow therapeutic index and is primarily renally eliminated. To optimize dosing of digoxin, therapeutic drug monitoring has been important since assays became available in the 1970s. Immunoassays are not specific, and cross-reactivity with endogenous and exogenous compounds has been reported for more than 20 years. Interassay concordance has not been investigated in recent years in “real-world” patient samples. Objective: To identify whether different digoxin immunoassays produce clinically different results in real-world situations, estimate the frequency of discordance, and determine whether an equation-based estimate compares well with digoxin immunoassays. Methods: Plasma samples were sent to 2 accredited laboratories simultaneously and the digoxin results were compared. Results of immunoassays conducted using the Cedia DRI Digoxin Assay and the DGNA Digoxin Assay were compared with an equation-based estimate of plasma digoxin concentration. Results: Thirty-six digoxin samples were assayed; in 39% of these, digoxin concentrations were discordant and different dosage adjustments would have followed. The presence of digoxin-like immunoreactive substances may explain some of this discordance. The mean of the equation-based result was similar to the Immunoassay results, but marked variability was evident. The DGNA assay produced higher results on 24 samples; 9 higher values occurred with the DRI method. Conclusions: Commercial digoxin immunoassays frequently produce clinically significant discordant results. The equation-based estimate does not appear to be an acceptable alternative to therapeutic drug monitoring. Immunoassay manufacturers should be required to improve assay performance by including real-world blood samples in development and clinicians should consider digoxin assay results warily.

Publisher

SAGE Publications

Subject

Pharmacology (medical)

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3