Anticoagulation Monitoring Part 2: Unfractionated Heparin and Low-Molecular-Weight Heparin

Author:

Spinler Sarah A1,Wittkowsky Ann K2,Nutescu Edith A3,Smythe Maureen A4

Affiliation:

1. Sarah A Spinler PharmD FCCP, Professor of Clinical Pharmacy, Adjunct Associate Professor of Pharmacy in Medicine, Cardiovascular Division, Department of Medicine, Philadelphia College of Pharmacy, University of Pennsylvania, Philadelphia, PA

2. Ann K Wittkowsky PharmD CACP FASHP, Professor of Clinical Pharmacy, School of Pharmacy, University of Washington; Director, Anticoagulation Services, University of Washington Medical Center, Seattle, WA

3. Edith A Nutescu PharmD, Clinical Associate Professor, Director, Antithrombosis Services, Department of Pharmacy Practice, College of Pharmacy, The University of Illinois at Chicago, Chicago, IL

4. Maureen A Smythe PharmD FCCP BCPS, Clinical Care Pharmacist, Department of Pharmaceutical Services, William Beaumont Hospital, Royal Oak, MI; Professor of Pharmacy Practice, Wayne State University, Detroit, MI

Abstract

OBJECTIVE To review the availability, mechanisms, limitations, and clinical application of point-of-care (POC) devices used in monitoring anticoagulation with unfractionated heparin (UFH) and low-molecular-weight heparins (LMWHs). DATA SOURCES Articles were identified through a MEDLINE search (1966–August 2004), device manufacturer Web sites, additional references listed in articles and Web sites, and abstracts from scientific meetings. STUDY SELECTION AND DATA EXTRACTION English-language literature from clinical trials was reviewed to evaluate the accuracy, reliability, and clinical application of POC monitoring devices. DATA SYNTHESIS The activated partial thromboplastin time (aPTT) and activated clotting time (ACT) are common tests for monitoring anticoagulation with UFH. Multiple devices are available for POC aPTT, ACT, and heparin concentration testing. The aPTT therapeutic range for UFH will vary depending upon the reagent and instrument employed. Although recommended by the American College of Chest Physicians Seventh Conference on Antithrombotic and Thrombolytic Therapy, establishing a heparin concentration–derived therapeutic range for UFH is rarely performed. Additional research evaluating anti-factor Xa monitoring of LMWHs using POC testing is necessary. CONCLUSIONS Multiple POC devices are available to monitor anticoagulation with UFH. For each test, there is some variability in results between devices and between reagents used in the same device. Despite these limitations, POC anticoagulation monitoring of UFH using aPTT and, more often, ACT is common in clinical practice, particularly when evaluating anticoagulation associated with interventional cardiology procedures and cardiopulmonary bypass surgery.

Publisher

SAGE Publications

Subject

Pharmacology (medical)

Cited by 64 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3