The Development and Implementation of a Novel Electronic Consult System by a Laboratory Medicine Service: Experience From the First 2 Years of Use

Author:

Stendahl Kristin123,Siddon Alexa J.13,Peaper David R.23,Hauser Ronald G.23,Campbell Sheldon23,Tormey Christopher A.23

Affiliation:

1. Department of Pathology (Stendahl, Siddon), Yale School of Medicine, New Haven, Connecticut

2. Department of Laboratory Medicine (Stendahl, Siddon, Peaper, Hauser, Campbell, Tormey), Yale School of Medicine, New Haven, Connecticut

3. Pathology & Laboratory Medicine Service (Stendahl, Siddon, Peaper, Hauser, Campbell, Tormey), VA Connecticut Healthcare System, West Haven, Connecticut

Abstract

Context.— A novel electronic consult (e-consult) system for a pathology and laboratory medicine service (PLMS) was implemented in 2015 at a high-complexity Veterans Administration health care facility. Consults were previously made through direct provider communication without documentation in the medical record. Objective.— To evaluate the utilization trends of the laboratory e-consult system at the Department of Veterans Affairs Connecticut facility during the first 2 years since inception. Design.— E-consultation involves pathology and laboratory medicine resident review followed by attending pathologist review and cosignature. E-consults to the pathology and laboratory medicine service from 2015 to 2017 were reviewed to record type of consult, requesting department, patient location, and turnaround time. Results.— The pathology and laboratory medicine service received 351 e-consults from 2015 to 2017. The volume varied by subsection: hematology and coagulation (215 of 351; 61%), chemistry (109 of 351; 31%), blood bank (19 of 351; 6%), and microbiology/virology (8 of 351; 2%). Hematology and coagulation consults were entirely for peripheral blood smear review (215 of 215; 100%). Chemistry consults were placed for toxicology/drugs of abuse (81 of 109; 74%), test utilization (17 of 109; 16%), or nontoxicology (11 of 109; 10%). Three services placed the majority of consults: primary care (279 of 351; 80%), hematology/oncology (39 of 351; 11%), and psychiatry (27 of 351; 8%). The median turnaround time for completion of e-consults was 1.2 days. Since e-consult implementation, the mean number of consults increased from 8.6/mo in 2015 to 18.1/mo in 2017, peaking in the last quarter of analysis in 2017 with a mean of 25.3 consults/mo. Conclusions.— This novel e-consult system improved accessibility to and documentation of answers to laboratory questions and increased the visibility of the pathology and laboratory medicine service. Future goals include development of outcomes-based measures to better assess the clinical impact of e-consults.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3