Comparative Performance of Breast Cancer Human Epidermal Growth Factor Receptor 2 Fluorescence In Situ Hybridization and Brightfield In Situ Hybridization on College of American Pathologists Proficiency Tests

Author:

Geiersbach Katherine B.1,Bridge Julia A.1,Dolan Michelle1,Jennings Lawrence J.1,Persons Diane L.1,Souers Rhona J.1,Tsuchiya Karen D.1,Vasalos Patricia H.1,Moncur Joel T.1

Affiliation:

1. From the Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota (Dr Geiersbach); the Department of Pathology and Microbiology, University of Nebraska Medical Center, Omaha (Dr Bridge); the Department of Laboratory Medicine and Pathology, University of Minnesota Medical School, Minneapolis (Dr Dolan); the Department of Pathology, Ann & Robert H. Lurie Children's Hospita

Abstract

Context.— Fluorescence in situ hybridization (FISH) and brightfield in situ hybridization (ISH) are 2 clinically approved laboratory methods for detecting ERBB2 (HER2) amplification in breast cancer. Objective.— To compare the performance of FISH and brightfield ISH on proficiency testing administered by the College of American Pathologists Laboratory Accreditation Program. Design.— Retrospective review was performed on 70 tissue core samples in 7 separate proficiency testing surveys conducted between 2009 and 2013. Results.— The samples included 13 consensus-amplified tissue cores, 53 consensus-nonamplified cores, and 4 cores that did not reach consensus for FISH and/or brightfield ISH. There were 2552 individual responses for FISH and 1871 individual responses for brightfield ISH. Consensus response rates were comparable for FISH (2474 of 2524; 98.0%) and brightfield ISH (2135 of 2189; 97.5%). The FISH analysis yielded an average HER2 copy number per cell that was significantly higher (by 2.86; P = .02) compared with brightfield ISH for amplified cores. For nonamplified cores, FISH yielded slightly, but not significantly, higher (by 0.17; P = .10) HER2 copy numbers per cell. There was no significant difference in the average HER2 to control ratio for either consensus-amplified or consensus-nonamplified cores. Participants reported “unable to analyze” more frequently for brightfield ISH (244 of 2453; 9.9%) than they did for FISH (160 of 2684; 6.0%). Conclusions.— Our study indicates a high concordance rate in proficiency testing surveys, with some significant differences noted in the technical performance of these assays. In borderline cases, updated American Society of Clinical Oncology/College of American Pathologists cutoff thresholds that place greater emphasis on HER2 copy number per cell could accentuate those differences between FISH and brightfield ISH.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3