Laboratory and Clinical Performance of the ADVIA Centaur Anticyclic Citrullinated Peptide Assay for Rheumatoid Arthritis Diagnosis

Author:

Kim Banseok1,Park Yongjung1,Park Jin-Su1,Jang Kyoung Ja1,Ahn Hyo Jun1,Choi Min Hyuk1,Lee Chan Hee1

Affiliation:

1. From the Department of Laboratory Medicine (Drs Kim, Y. Park, and Choi; Ms Jang; and Mr Ahn) and the Division of Rheumatology, Department of Internal Medicine (Drs J.-S. Park and Lee), National Health Insurance Service Ilsan Hospital, Goyang, Republic of Korea.

Abstract

Context.— Anticyclic citrullinated peptide antibodies are important serologic markers for the diagnosis of rheumatoid arthritis. Several kinds of test reagents for automated immunoassay systems have been developed and used in recent years. Objective.— To evaluate the analytic and diagnostic performance of the new ADVIA Centaur anticyclic citrullinated peptide assay (Siemens Healthineers, Erlangen, Germany) compared with the Elecsys assay (Roche Diagnostics, Mannheim, Germany). Design.— A total of 576 serum samples were collected from subjects, including 156 patients (27%) with rheumatoid arthritis. Precision performance and analytical measurement range for the ADVIA assay were evaluated. Diagnostic performance of the 2 assays was compared based on sensitivity, specificity, and area under the receiver operating characteristic curves. Results.— The ADVIA assay showed a within-laboratory imprecision of 3.4% coefficient of variation for levels of 3.36 and 24.99 U/mL. This assay was demonstrated to be linear from 0.4 to 180.0 U/mL. With default cutoff values, sensitivity and specificity for diagnosing rheumatoid arthritis were 71.2% and 97.9%, respectively, for the ADVIA assay and 73.1% and 96.9%, respectively, for the Elecsys assay. With the best cutoff values from the analyses of the receiver operating characteristic curve, the sensitivity of the 2 assays was the same at 75.6%. However, the specificity of the ADVIA assay was 96.4%, whereas that of the Elecsys assay was 94.3%. The area under the receiver operating characteristic curve value for the ADVIA assay was 0.867, which was not significantly different from that of the Elecsys assay (0.865). Conclusions.— The ADVIA Centaur anticyclic citrullinated peptide assay showed good analytic and diagnostic performance in diagnosing rheumatoid arthritis.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3