Outpatient Phlebotomy Success and Reasons for Specimen Rejection

Author:

Dale Jane C.1,Novis David A.1

Affiliation:

1. From the Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minn (Dr Dale); and the Department of Pathology, Wentworth-Douglass Hospital, Dover, NH (Dr Novis)

Abstract

Abstract Objectives.—To determine the rate with which blood collection is successful on the initial phlebotomy encounter, the rate with which laboratory personnel judge specimens unsuitable for analysis, and the practice characteristics associated with fewer unsuccessful collections and fewer rejected specimens. Design.—Clinical laboratories participating in the College of American Pathologists Q-Probes laboratory improvement program prospectively characterized the outcome of outpatient phlebotomies for 3 months or until 20 unsuccessful phlebotomy encounters occurred. By questionnaire, participants provided information about test ordering, patient preparation, and specimen collection. Setting and Participants.—Institutions in the United States (n = 202), Canada (n = 4), Australia (n = 3), and South Korea (n = 1). Main Outcome Measures.—Percentage of successful encounters and percentage of unsuitable specimens. Results.—Of 833289 encounters, 829723 were successful. Phlebotomies were unsuccessful because patients were not fasting as directed (32.2%), phlebotomy orders were missing information (22.5%), patients specimens were difficult to draw (13.0%), patients left the collection area before specimens were collected (11.8%), patients were improperly prepared for reasons other than fasting (6.3%), patients presented at the wrong time (3.1%), or for other reasons (11.8%). Only 2153 specimens (0.3%) were unsuitable; these samples were hemolyzed (18.1%), of insufficient quantity (16.0%), clotted (13.4%), lost or not received in the laboratory (11.5%), inadequately labeled (5.8%), at variance with previous or expected results (4.8%), or unacceptable for other reasons (31.1%). Facilities staffed by laboratory-administered phlebotomists reported higher success rates than facilities staffed by nonlaboratory-administered phlebotomists (P = .002). Conclusions.—Most outpatient phlebotomy encounters are successful and result in specimens suitable for laboratory analysis.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

Cited by 33 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3