Abstract

Abstract Context.—Quantitation of hemoglobin (Hb) A1c and investigation of hemoglobinopathy on the Bio-Rad Variant analyzers require a switch between 2 separate kits that is time consuming and causes errors. Objective.—Evaluation of a new Variant II HbA2/HbA1c Dual kit capable of both Hb A1c quantitation and hemoglobinopathy investigation on a single kit. Design.—We evaluated Hb A1c, Hb A2, and Hb F quantitation for precision, linearity, and correlation with current methodology. We also evaluated detection of Hb variants and correlation of Hb Barts quantitation. Setting.—Hamilton Regional Laboratory Medicine Program, Provincial Hemoglobinopathy Laboratory, St Joseph's Healthcare Site, Hamilton, Ontario. Patients.—Patient blood samples submitted for Hb A1c quantitation or hemoglobinopathy investigation. Main Outcome Measures.—Precision, linearity, linear regression, and reference interval validation. Results.—We provide tables and figures illustrating precision, linearity, linear regression, and quantitation of Hb variants. We validated reference intervals for Hb A1c, Hb A2, and Hb F. Conclusions.—The dual kit provides precise Hb A1c, Hb A2, and Hb F quantitation. The results show good linearity and correlate well with the results of current methods. We detected all clinically important Hb variants and a wide variety of rare variants. The dual kit has several advantages: it eliminates the need for extensive kit switch over; improves utility for newborn screening because of its quantification of Hb Barts; permits quantification of Hb A1c using the β-Thal method; and eliminates the need for separate Hb A2 reference intervals for patients with Hb S because of its accurate quantitation of Hb A2 in the presence of Hb S.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3