Platelet Count Monitoring and Laboratory Testing for Heparin-Induced Thrombocytopenia

Author:

Warkentin Theodore E.1

Affiliation:

1. From the Department of Pathology and Molecular Medicine and the Department of Medicine, McMaster University; Transfusion Medicine, Hamilton Regional Laboratory Medicine Program; and Service of Clinical Hematology, Hamilton, Ontario

Abstract

Abstract Objective.—Heparin-induced thrombocytopenia (HIT) is an antibody-mediated adverse drug reaction that paradoxically is associated with a brief but dramatically increased risk for thrombosis (transient acquired thrombophilia). The objective of this article is to provide practical recommendations for platelet count monitoring in patients receiving heparin, as well as for selection of laboratory assays to detect pathogenic HIT antibodies. Study Selection.—Relevant literature that focused on frequency and timing of HIT in various clinical settings and that dealt with laboratory testing for HIT antibodies was critically appraised. Data Extraction and Synthesis.—The author prepared a preliminary manuscript including recommendations that was presented to participants at the College of American Pathologists Conference XXXVI: Diagnostic Issues in Thrombophilia (November 10, 2001). Support of at least 70% of conference participants was required for recommendations to be adopted. Conclusions.—The risk of immune HIT varies depending on the type of heparin (unfractionated heparin greater than low-molecular-weight heparin) and patient population (surgical greater than medical). Thus, the intensity of platelet count monitoring should be stratified depending on the clinical situation. Platelet count monitoring should focus on the period of highest risk (usually days 5 to 10 after starting heparin) and should use an appropriate platelet count baseline (generally, the highest platelet count beginning 4 days after start of heparin). However, earlier platelet count monitoring is appropriate if the patient received heparin within the past 100 days, as already circulating HIT antibodies can cause rapid-onset HIT with heparin reexposure. Although both antigen and (washed platelet) activation assays are very sensitive for detecting clinically significant HIT antibodies, activation assays have greater diagnostic specificity for clinical HIT.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

Cited by 91 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3