Mislabeling of Cases, Specimens, Blocks, and Slides: A College of American Pathologists Study of 136 Institutions

Author:

Nakhleh Raouf E,Idowu Michael O,Souers Rhona J,Meier Frederick A,Bekeris Leonas G

Abstract

Context.—Accurate specimen labeling is a major patient-safety initiative by the Joint Commission and the College of American Pathologists. Inadequate specimen labels have led to patient injury from wrong patient diagnosis, wrong side treatment, and delay in diagnosis.Objectives.—To quantify the rates of mislabeled cases, specimens, blocks, and slides and to identify the sources of error and the ways in which errors are detected.Design.—In this voluntary-subscription Q-Probes study, participants prospectively reviewed surgical pathology cases for 8 weeks or until 30 errors (mislabeled cases, specimens, blocks, and slides) were identified. Information collected on each labeling error included the work location where the defect occurred, what was mislabeled, the number of items affected, the point of detection, and the consequences of the mislabeling error, along with institutional demographics and practice. The rates of mislabeled cases, specimens, blocks, and slides were tested for association with institutional demographics and practice variables.Results.—Of the 136 institutions providing information on a total of 1811 mislabeling occurrences, the overall mislabeling rates per 1000 were 1.1 cases, 1.0 specimen, 1.7 blocks, and 1.1 slides. Of all mislabeling events, 27.1% were cases, 19.8% specimens, 25.5% blocks, and 27.7% slides. The work locations at which the errors occurred were 20.9% before accessioning, 12.4% at accessioning, 21.7% at block labeling, 10.2% during gross pathology, and 30.4% at tissue cutting. Errors were typically detected in the first or second steps immediately following the error. Lower mislabeled slide rates were associated with continuous individual case accessioning and use of formal checks at accessioning. Routinely including a statement in the gross description that the specimen is labeled with the patient's name and is properly identified was also associated with lower rates of specimen mislabeling. The errors were corrected before reports were issued 96.7% of the time; for 3.2% of errors, a corrected report was issued. In 1.3% of error occurrences, participants gauged that patient care was affected.Conclusions.—This study quantified mislabeling rates across 136 institutions of cases (0.11%), specimens (0.1%), blocks (0.17%), and slides (0.11%). Errors in labeling appear nearly equally throughout the system of accessioning, gross pathology processing, and tissue cutting. Errors are typically detected in the immediate steps after the errors occurred, reinforcing the need for quality checks throughout the system.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3