An Evaluation of the Performance of Sysmex XE-2100 in Enumerating Nucleated Red Cells in Peripheral Blood

Author:

Gulati Gene1,Behling Eric1,Kocher William1,Schwarting Roland1

Affiliation:

1. From the Department of Pathology, Anatomy, and Cell Biology, Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pa (Drs Gulati, Behling, Kocher, and Schwarting); and the Department of Pathology, Cooper University Hospital, Camden, NJ (Dr Schwarting)

Abstract

Abstract Context.—Automated methods of enumerating nucleated red blood cells (NRBCs) in blood are gaining acceptance in many laboratories. Objective.—To evaluate the performance of Sysmex XE-2100 in enumerating NRBCs in peripheral blood. Design.—Automated relative number of NRBCs per 100 white blood cells (NRBC%) results for a total of 460 specimens run on the XE-2100 were compared with manual NRBC% results obtained by performing a 100-cell differential on a Wright-stained smear prepared from each specimen. To assess within-day reproducibility, 64 specimens were rerun on the XE-2100, and a second 100-cell differential was performed on the original blood smear. Excel software was used for data analysis. Results.—Regression analysis of automated NRBC% versus manual NRBC% yielded a correlation coefficient of 0.9712. No NRBCs were seen in the blood smear on 35 (15.1%) of 232 specimens with automated NRBC% of 0.1 to 1.9. The XE-2100 generated an NRBC% of 0.0 on 5 (6.8%) of 74 specimens, revealing 1 NRBC per 100 or more white blood cells by blood smear examination. The mean percent difference between duplicate automated results was 16.7 compared with 78.1 for the duplicate manual results. There were 9 instances in which the XE-2100 either did not detect the presence of more than 8 NRBCs per 100 white blood cells or generated an automated NRBC% of 18.1 or 18.8 when the smear revealed none. All of these were, however, flagged for smear review. Conclusions.—Overall correlation between the automated and manual results was excellent. The automated method revealed better precision than the manual method. The number of specimens with false automated results was very small, and all were flagged for verification by a smear review.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3