Therapeutic Drug Monitoring of Second- and Third-Generation Antiepileptic Drugs

Author:

Krasowski Matthew D.1,Long Thomas A.2,Snozek Christine L. H.3,Dizon Annabel4,Magnani Barbarajean5,Melanson Stacy E. F.6

Affiliation:

1. From the Department of Pathology, University of Iowa Hospitals and Clinics, Iowa City (Krasowski)

2. The Department of Biostatistics (Long), College of American Pathologists, Northfield, Illinois

3. The Department of Laboratory Medicine and Pathology, Mayo Clinic in Arizona, Scottsdale (Snozek)

4. The Proficiency Testing Division (Dizon), College of American Pathologists, Northfield, Illinois

5. The Department of Pathology and Laboratory Medicine, Tufts Medical Center, and the Department of Anatomic and Clinical Pathology, Tufts University School of Medicine, Boston, Massachusetts (Magnani)

6. The Department of Pathology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts (Melanson)

Abstract

Context.— Therapeutic drug monitoring has traditionally been widely used for first-generation antiepileptic drugs (AEDs) such as carbamazepine and phenytoin. The last 2 decades have seen the introduction of second- and third-generation AEDs (eg, lamotrigine, levetiracetam, and topiramate) into clinical practice. Objective.— To use data from the College of American Pathologists Therapeutic Drug Monitoring, Extended Proficiency Testing Survey to determine the performance of assays used for therapeutic drug monitoring of newer AEDs, including comparison of enzyme immunoassay and chromatographic techniques. Design.— Six years of proficiency testing surveys were reviewed (2013–2018). Results.— Steady growth was seen in participant volumes for newer AEDs. The analytical performance of automated enzyme immunoassays for lamotrigine, levetiracetam, and topiramate was similar to that of chromatographic methods, consistent with published literature using patient samples for comparisons. The majority of participating laboratories now use enzyme immunoassays to measure levetiracetam. Conclusions.— Survey results reflect steadily growing interest in therapeutic drug monitoring of newer AEDs. The increasing availability of robust immunoassays for new AEDs should facilitate their clinical utility, especially for clinical laboratories that do not perform chromatographic assays for therapeutic drug monitoring.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3