International Council for Standardization in Haematology Field Study Evaluating Optimal Interpretation Methods for Activated Partial Thromboplastin Time and Prothrombin Time Mixing Studies

Author:

Gosselin Robert C.1,Moore Gary W.23,Kershaw Geoffrey W.4,Montalvão Silmara5,Adcock Dorothy M.6

Affiliation:

1. From the Hemostasis & Thrombosis Center, University of California, Davis Health System, Sacramento (Gosselin)

2. The Department of Haematology, Specialist Haemostasis Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom (Moore)

3. The Department of Natural Sciences, Faculty of Science and Technology, Middlesex University, London, United Kingdom (Moore)

4. The Institute of Haematology, Royal Prince Alfred Hospital, Sydney, NSW, Australia (Kershaw)

5. Laboratory Hemostasis and Thrombosis, Hematology and Hemotherapy Center, University of Campinas UNICAMP, Campinas-SP, Brazil (Montalvão)

6. Labcorp, Burlington, North Carolina (Adcock)

Abstract

Context.— The prothrombin time (PT) and activated partial thromboplastin time (APTT) are screening tests used to detect congenital or acquired bleeding disorders. An unexpected PT and/or APTT prolongation is often evaluated using a mixing test with normal plasma. Failure to correct (“noncorrection”) prolongation upon mixing is attributed to an inhibitor, whereas “correction” points to factor deficiency(ies). Objective.— To define an optimal method for determining correction or noncorrection of plasma mixing tests through an international, multisite study that used multiple PT and APTT reagents and well-characterized plasma samples. Design.— Each testing site was provided 22 abnormal and 25 normal donor plasma samples, and mixing studies were performed using local PT and APTT reagents. Mixing study results were evaluated using 11 different calculation methods to assess the optimal method based on the expected interpretation for factor deficiencies (correction) and noncorrection (inhibitor effect). Misprediction, which represents the failure of a mixing study interpretation method, was assessed. Results.— Percentage correction was the most suitable calculation method for interpreting PT mixing test results for nearly all reagents evaluated. Incubated PT mixing tests should not be performed. For APTT mixing tests, percentage correction should be performed, and if the result indicates a factor deficiency, this should be confirmed with the subtraction III calculation where the normal pooled plasma result (run concurrently) is subtracted from the mixing test result with correction indicated by a result of 0 or less. In general, other calculation methods evaluated that performed well in the identification of factor deficiency tended to have high misprediction rates for inhibitors and vice versa. Conclusions.— No single method of mixing test result calculation was consistently successful in accurately distinguishing factor deficiencies from inhibitors, with between-reagent and between-site variability also identified.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Assessing Direct Oral Anticoagulants in the Clinical Laboratory;Clinics in Laboratory Medicine;2024-09

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3