An International Survey of Glucose-6-Phosphate Dehydrogenase Laboratory Reporting Practices: Implications for Tafenoquine Eligibility Assessment

Author:

Genzen Jonathan R.12,Nwosu Ann3,Long Thomas3,Murphy Hilda4,Alter David N.5

Affiliation:

1. From the Department of Pathology, University of Utah, Salt Lake City, Utah (Genzen).

2. From ARUP Laboratories, Salt Lake City, Utah (Genzen).

3. From the Division of Biostatistics (Nwosu, Long), College of American Pathologists, Northfield, Illinois.

4. From Proficiency Testing (Murphy), College of American Pathologists, Northfield, Illinois.

5. From the Department of Pathology and Laboratory Medicine, Emory University School of Medicine, Atlanta, Georgia (Alter).

Abstract

Context.— Glucose-6-phosphate dehydrogenase (G6PD) activity is used in the evaluation of hemolysis risk in patients being assessed for G6PD deficiency. A long-acting 8-aminoquinoline drug (tafenoquine) used in malaria treatment is contraindicated in patients with G6PD deficiency (<70% normal G6PD activity). The current state of G6PD reporting practices to support clinical eligibility assessment is poorly understood. Objective.— To assess clinical laboratory reporting practices for G6PD testing. Design.— In October 2019 and October 2020, voluntary questionnaires were distributed to 327 and 324 laboratories participating in the College of American Pathologists G6PD proficiency testing (PT). Results.— Two hundred fifty-seven and 119 laboratories responded to the 2019 and 2020 questionnaires, respectively. Few laboratories have received clinical questions about average normal G6PD activity (US/Canada, 2.0% [3 of 149]; international, 8.4% [9 of 107]), whereas slightly more have determined the average normal G6PD activity for their own assay and patient populations (US/Canada, 6.7% [10 of 149]; international, 19.4% [21 of 108]). Few laboratories report G6PD activity in percent of normal format (US/Canada, 2.7% [4 of 149]; international, 8.3% [9 of 108]). The most common unit of measurement in use for quantitative G6PD reporting is unit per gram of hemoglobin. Reference intervals vary based on assay, reaction temperature, and participant laboratory and demonstrate moderate correlation (r = .46–.51) to G6PD activity measured from a “normal” PT challenge specimen. Nearly half of participants (47.8% [85 of 178]) categorized a quantitatively “intermediate” G6PD PT challenge as “normal” when using qualitative assays. Conclusions.— Percent of normal G6PD activity reporting would facilitate patient eligibility assessment for drugs, such as tafenoquine. Quantitative assays are better able to differentiate “intermediate” specimens than qualitative assays.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3