Initial Evaluation of Rapid, Direct-to-Digital Prostate Biopsy Pathology

Author:

Torres Richard1,Olson Eben1,Homer Robert23,Martin Darryl T.4,Levene Michael J.5,Perincheri Sudhir2,Sprenkle Preston C.4,Humphrey Peter A.2

Affiliation:

1. The Department of Laboratory Medicine (Torres, Olson), Yale School of Medicine, New Haven, Connecticut

2. The Department of Pathology (Homer, Perincheri, Humphrey), Yale School of Medicine, New Haven, Connecticut

3. The Pathology and Laboratory Medicine Service, VA Connecticut Healthcare System, West Haven (Homer)

4. The Department of Urology (Martin, Sprenkle), Yale School of Medicine, New Haven, Connecticut

5. Applikate Technologies, LLC, Washington, DC (Levene)

Abstract

Context.— Pathologist interobserver discordance is significant in grading of prostate cancer, limiting reliability. Diagnostic reproducibility may be improved with digital images, but adoption faces workflow, cost, and quality challenges. A novel digital method using an alternative tissue processing approach and novel laser microscopy system potentially addresses these issues. Objective.— To evaluate the capability of this new method for primary diagnostic interpretation in clinical prostate biopsy specimens. Design.— Forty patients with a high likelihood of prostate cancer based on magnetic resonance imaging consented to investigational core biopsy. A subset of samples was used for direct comparison of physical slide preparation effects and time-tracking determination with multiphoton microscopy. Twenty samples were processed for diagnostic comparison between multilevel digital slides and subsequently produced physical slides. A reference diagnosis based on all data was established using grade groups. Level of diagnostic match and requests for immunohistochemistry were compared between physical and digital diagnoses. Immunohistochemical staining and length measurements were secondary outcomes. Results.— Interpretations based on direct multiphoton imaging yielded diagnoses that were at least as accurate as standard histology; cancer diagnosis correlation was 89% (51 of 57) by physical slides and 95% (53 of 56) by multiphoton microscopy. Grade-level concordance was 73% (44 of 60) by either method. Immunohistochemistry for routine prostate cancer–associated markers on these alternatively processed tissues was unaffected. Alternatively processed tissues resulted in longer measured core and cancer lengths, suggestive of improved orientation and visualization. Conclusions.— Findings support high potential for complete interpretation of prostate core biopsies using solely multiphoton microscopy of intact specimens, with potential diagnostic benefits as well as reduced processing time and reduced processing complexity.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3