Identifying Inconclusive Data in the SARS-CoV-2 Molecular Diagnostic Using Nucleocapsid Phosphoprotein Gene as Target

Author:

Klein Raphael Contelli1,Fabres Klein Mary Hellen1,Barbosa Larissa Gomes1,Gonzaga Knnup Lívia Vasconcelos1,Rodrigues Venâncio Larissa Paola1,Lima Jonilson Berlink1,Araújo-Santos Théo1

Affiliation:

1. Infectious Agents and Vectors Research Group at the Center for Biological and Health Sciences, Federal University of Western Bahia, Barreiras, Bahia, Brazil

Abstract

ABSTRACT Context: The gold standard test to identify the presence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in coronavirus disease 2019 (COVID-19) patients is the real-time reverse transcription quantitative polymerase chain reaction (RT-qPCR), but the inconclusive data and presence of false positive diagnosis remain the major problem of this approach. Objective: To compare the fitness of two primers sets to the SARS-CoV-2 nucleocapsid phosphoprotein (NP) gene in the molecular diagnosis of COVID-19, we verify the inconclusive data and confidence of high cycle threshold (Ct) values in the SARS-CoV-2 detection. Design: The 970 patient samples were tested using United States Centers for Disease Control and Prevention protocol. We compared the fitness of two primers sets to two different regions of NP gene. In addition, we check the consistency of positive samples with high Ct values by retesting extracted SARS-CoV-2 RNA or by second testing of patients. Results: The N1 and N2 displayed similar fitness during testing with no differences between Ct values. Then, we verified security range Cts related to positive diagnostic with Ct above 34 failing in 21/32 (65.6%) after retesting of samples. The samples patients with Ct above 34.89 that were doubly positive revealed a low sensitivity (52.4%) and specificity (63.6%) of the test in samples with Ct above 34. Conclusions: It is secure to use one primer set to the NP gene to identify SARS-CoV-2 in samples. However, samples with high Ct values may be considered inconclusive and retested to avoid false positive diagnosis.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Quality of the sample-based RNA determines the real-time RT-PCR results in the laboratory diagnosis of COVID-19;Diagnostic Microbiology and Infectious Disease;2024-01

2. Borderline SARS-CoV-2 patients: the trace behind;Expert Review of Molecular Diagnostics;2023-04-03

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3