Standardization of HER2 Immunohistochemistry in Breast Cancer by Automated Quantitative Analysis

Author:

Gustavson Mark D.12,Bourke-Martin Brian2,Reilly Dylan2,Cregger Melissa2,Williams Christine2,Mayotte Jane2,Zerkowski Maciej2,Tedeschi Greg2,Pinard Robert2,Christiansen Jason2

Affiliation:

1. Reprints: Mark D. Gustavson, PhD, Department of Development, HistoRx Inc, 300 George St, New Haven, CT 06511 (mgustavson@historx.com).

2. From the Departments of Development (Drs Gustavson and Christiansen, Messrs Bourke-Martin, Reilly, Zerkowski, and Tedeschi, and Mss Cregger, Williams, and Mayotte) and Pharmaceutical Services (Dr Pinard), HistoRx Inc, New Haven, Connecticut.

Abstract

Abstract Context.—There is critical need for standardization of HER2 immunohistochemistry testing in the clinical laboratory setting. Recently, the American Society of Clinical Oncology and the College of American Pathologists have submitted guidelines recommending that laboratories achieve 95% concordance between assays and observers for HER2 testing. Objective.—As a potential aid to pathologists for achieving these new guidelines, we have conducted an examination using automated quantitative analysis (AQUA analysis) to provide a standardized HER2 immunohistochemistry expression score across instruments (sites), operators, and staining runs. Design.—We analyzed HER2 expression by immunohistochemistry in a cohort (n = 669) of invasive breast cancers in tissue microarray format across different instruments (n = 3), operators (n = 3), and staining runs (n = 3). Using light source, instrument calibration techniques, and a new generation of image analysis software, we produced normalized AQUA scores for each parameter and examined their reproducibility. Results.—The average percent coefficients of variation across instruments, operators, and staining runs were 1.8%, 2.0%, and 5.1%, respectively. For positive/negative classification between parameters, concordance rates ranged from 94.5% to 99.3% for all cases. Differentially classified cases only occurred around the determined cut point, not over the entire distribution. Conclusions.—These data demonstrate that AQUA analysis can provide a standardized HER2 immunohistochemistry test that can meet current guidelines by the American Society of Clinical Oncology/College of American Pathologists. The use of AQUA analysis could allow for standardized and objective HER2 testing in clinical laboratories.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3