Patient Misidentification in Laboratory Medicine: A Qualitative Analysis of 227 Root Cause Analysis Reports in the Veterans Health Administration

Author:

Dunn Edward J.,Moga Paul J.

Abstract

Abstract Context Mislabeled laboratory specimens are a common source of harm to patients, such as repeat phlebotomy; repeat diagnostic procedure, including tissue biopsy; delay in a necessary surgical procedure; and the execution of an unnecessary surgical procedure. Mislabeling has been estimated to occur at a rate of 0.1% of all laboratory and anatomic pathology specimens submitted. Objective To identify system vulnerabilities in specimen collection, processing, analysis, and reporting associated with patient misidentification involving the clinical laboratory, anatomic pathology, and blood transfusion services. Design A qualitative analysis was performed on 227 root cause analysis reports from the Veterans Health Administration. Content analysis of case reports from March 9, 2000, to March 1, 2008, was facilitated by a Natural Language Processing program. Data were categorized by the 3 stages of the laboratory test cycle. Results Patient misidentification accounted for 182 of 253 adverse events, which occurred in all 3 stages of the test cycle. Of 132 misidentification events occurring in the preanalytic phase, events included wrist bands labeled for the wrong patient were applied on admission (n  =  8), and laboratory tests were ordered for the wrong patient by selecting the wrong electronic medical record from a menu of similar names and Social Security numbers (n  =  31). Specimen mislabeling during collection was associated with “batching” of specimens and printed labels (n  =  35), misinformation from manual entry on laboratory forms (n  =  14), failure of 2-source patient identification for clinical laboratory specimens (n  =  24), and failure of 2-person verification of patient identity for blood bank specimens (n  =  20). Of 37 events in the analytic phase, relabeling all specimens with accession numbers was associated with mislabeled specimen containers, tissue cassettes, and microscopic slides (n  =  27). Misidentified microscopic slides were associated with a failure of 2-pathologist verification for cancer diagnosis (n  =  4), and wrong patient transfusions were associated with mislabeled blood products (n  =  3) and a failure of 2-person verification for blood products before release by the blood bank (n  =  3). There were 13 events in the postanalytic phase in which results were reported into the wrong patient medical record (n  =  8), and incompatible blood transfusions were associated with failed 2-person verification of blood products (n  =  5). Conclusions Patient misidentification in the clinical laboratory, anatomic pathology, and blood transfusion processes were due to a limited set of causal factors in all 3 phases of the test cycle. A focus on these factors will inform systemic mitigation and prevention strategies.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

Cited by 29 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3