Correction Factors for Estimating Potassium Concentrations in Samples With In Vitro Hemolysis: A Detriment to Patient Safety

Author:

Mansour Mai M. H.1,Azzazy Hassan M. E.1,Kazmierczak Steven C.1

Affiliation:

1. From the Department of Chemistry, American University in Cairo, Cairo, Egypt (Drs Mansour and Azzazy); and the Department of Pathology, Oregon Health & Science University, Portland, Ore (Dr Kazmierczak)

Abstract

Abstract Context.—Correction factors have been proposed for estimating true potassium concentrations in blood samples with evidence of in vitro hemolysis. Objective.—We used 2 different models of true (ie, nonsimulated) in vitro hemolysis to evaluate the clinical utility of correction factors for estimating potassium concentrations in samples with evidence of in vitro hemolysis. Design.—Potassium correction factors were derived using 2 different models. In model 1, potassium and plasma hemoglobin were measured with the Hitachi 747 analyzer in 132 paired blood samples, with each pair consisting of 1 sample with evidence of hemolysis and 1 without, collected during the same phlebotomy procedure. The change in measured potassium concentration was plotted versus the change in plasma hemoglobin concentration for each pair of samples. In model 2, the potassium levels of 142 784 blood samples and the corresponding hemolytic index values were measured with the Beckman LX20 analyzer. Potassium concentrations at the 10th, 25th, 50th, 75th, and 90th percentiles were calculated for each hemolysis index category. Results.—From our 2 models, we derived correction factors expressing an increase in potassium concentration of 0.51 and 0.40 mEq/L for every increase in plasma hemoglobin concentration of 0.1 g/dL. These correction factors are much higher than those reported in studies that simulated in vitro hemolysis by freeze-thaw lysis or osmotic disruption of whole blood. Conclusions.—Use of correction factors for estimating the true potassium concentration in samples with evidence of in vitro hemolysis is not recommended. Derivation of correction factors by using samples with nonsimulated in vitro hemolysis suggests that the actual increase in potassium in hemolyzed samples is much higher than that reported in previous studies that produced hemolysis with artificial means.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3