Influence of Sampling Time and Ultrafiltration Coefficient of the Dialysis Membrane on Cardiac Troponin I and T

Author:

Lippi Giuseppe1,Tessitore Nicola1,Montagnana Martina1,Salvagno Gian Luca1,Lupo Antonio1,Guidi Gian Cesare1

Affiliation:

1. From the Sezione di Chimica Clinica, Dipartimento di Scienze Morfologico-Biomediche (Drs Lippi, Montagnana, Salvagno, and Guidi) and the Sezione di Nefrologia, Dipartimento di Scienze Biomediche e Chirurgiche (Drs Tessitore and Lupo), Università degli Studi di Verona, Italy

Abstract

Abstract Context.—The measurement of cardiac troponin I (TnI) and T (TnT) is essential to diagnose, guide therapy, and predict outcomes of the acute coronary syndrome. Increased levels of troponins, especially TnT, are frequently observed in patients on chronic hemodialysis (HD), reflecting ongoing and subclinical myocardial damage. Objective.—Because these markers are increasingly used for stratification of cardiac risk in these patients, their behavior during HD should be acknowledged to optimize their clinical usefulness. Design.—TnI and TnT were measured in 34 patients pre-HD and post-HD by either high- or low-flux membranes. The post-HD concentrations were corrected for hemoconcentration. Results.—Pre-HD levels above the 99th percentile reference limits of the general population of TnI (>0.06 ng/ mL) and TnT (>0.01 ng/mL) were observed in 9% (13% high-flux, 6% low-flux membranes) and 88% (94% high-flux; 83% low-flux membranes) of the patients, respectively. No significant difference was observed in mean pre-HD values between patients dialyzed by low- and high-flux membranes. The overall decrease post-HD of both troponins (−21% and −17% for TnI and TnT, respectively) only reached statistical significance in patients dialyzed by low-flux membranes (−27% and −37% for TnI and TnT, respectively). A significant correlation was observed between absolute variations of TnI and TnT pre-HD to post-HD. Conclusions.—Results of our investigation attest that high-flux membranes clear both troponins more efficiently from circulation than low-flux membranes. Therefore, sampling time and ultrafiltration coefficient of the HD membrane should be regarded as potential sources of variability in the clinical interpretation of troponin measurement in HD patients.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3