Evaluation of the BiliChek Being Used on Hyperbilirubinemic Newborns Undergoing Home Phototherapy

Author:

Reyes Christine A.1,Stednitz Donald R.1,Hahn Carol1,Mutchie Kelly D.1,McCullough Steven R.1,Kronberg Kent1

Affiliation:

1. From the Department of Pathology (Dr Reyes, Ms Hahn, and Mr McCullough), Children's Home Health Care (Mr Stednitz and Dr Mutchie), and Children's Physicians Eagle Run (Dr Kronberg), Children's Hospital, Omaha, Neb

Abstract

Abstract Context.—Newborns are often screened prior to discharge for hyperbilirubinemia. Transcutaneous bilirubin analyzers, such as the BiliChek, are promoted as screening tools, but it is unclear whether they also function well as monitoring devices. Newborns on home phototherapy require frequent determinations of serum bilirubin levels to monitor therapy effects. A transcutaneous bilirubin analyzer would be helpful to limit blood draws and enhance staff efficiency. We evaluated the accuracy of the BiliChek analyzer in this setting. Objective.—Is the BiliChek sufficiently accurate to monitor the effectiveness of home phototherapy and establish when to terminate therapy? Design.—Paired serum bilirubin results and results from the BiliChek were obtained from newborns on home phototherapy during daily home health care visits. Results.—The BiliChek demonstrates a negative bias (mean bias, −1.71 mg/dL; 95% confidence interval, −1.89 to −1.52 mg/dL) compared with serum bilirubin values. This bias worsens as the serum bilirubin level rises. If a value of 14 mg/dL or less obtained using the BiliChek had been used as the cutoff for termination of phototherapy, 45% of newborns would have had therapy terminated prematurely. If, knowing the negative bias of the BiliChek, the cutoff for termination of therapy was set at less than or equal to 11 mg/dL, then 29% of newborns would have had therapy terminated prematurely. Conclusions.—The values obtained using the BiliChek, compared to serum bilirubin values, have a negative bias that worsens at the higher bilirubin levels expected in newborns at home on phototherapy. The BiliChek does not provide sufficient accuracy to be utilized to monitor newborns on home phototherapy or to ascertain when to discontinue such therapy.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3