Reference Standardization and Analytical Performance of a Liquid Homogeneous High-Density Lipoprotein Cholesterol Method Compared With Chemical Precipitation Method

Author:

Halloran Paul1,Roetering Hinke1,Pisani Thomas1,van den Berg Bea1,Cobbaert Christa1

Affiliation:

1. From Diagnostics Research and Development, Genzyme Diagnostics, Cambridge, Mass (Mr Halloran and Mr Pisani); the Lipid Reference Laboratory, University Hospital Rotterdam, The Netherlands (Ms Roetering, Ms van den Berg, and Dr Cobbaert); and the Department of Clinical Chemistry, De Baronie Hospital, Breda, The Netherlands (Dr Cobbaert).

Abstract

Abstract Background.—The use of high-density lipoprotein cholesterol (HDL-C) levels as a risk factor for coronary heart disease necessitates an accurate and precise method for measuring HDL-C. The Centers for Disease Control and Prevention HDL-C reference method (RM) and designated comparison method (DCM) are time-consuming, expensive, and impractical for routine clinical use. We evaluated the Liquid N-geneous (LN-gen) HDL-C assay (Genzyme Diagnostics, Cambridge, Mass) to determine if this homogeneous reagent meets the National Cholesterol Education Program requirements for HDL-C evaluation. Design.—Accuracy of the LN-gen HDL-C assay was compared in combination with phosphotungstic acid (PTA) precipitation with DCM HDL-C for normotriglyceridemic serum specimens (triglycerides <2.0 g/L) and with RM HDL-C for specimens with triglycerides levels ≥2.0 g/L. Setting.—Genzyme Diagnostics (with RM and DCM assayed by Pacific BioMetrics Inc, Seattle, Wash) and the Lipid Reference Laboratory of the University Hospital Rotterdam, The Netherlands. Results.—Linear regression to DCM (n = 90) was (LN-gen = 1.015 DCM + 0.01 g/L, r = 0.993, SE = 0.015 g/L) and (PTA = 1.004 DCM − 0.017 g/L, r = 0.980, SE = 0.025 g/L), with a mean percent bias to DCM of 3.3% and −2.8% for LN-gen and PTA, respectively. The comparison with RM (n = 69) showed an increased mean bias for PTA (−5.8%) as compared with LN-gen (1.5%). The correlation and regression equations were (LN-gen = 1.020 RM − 0.002 g/L, r = 0.985, SE = 0.017 g/L) and (PTA = 1.042 RM − 0.032 g/L, r = 0.984, SE = 0.018 g/L). The precision of LN-gen was confirmed at <2.1% coefficient of variation, and the total error was calculated to be ≤7.7% for both normotriglyceride and elevated triglyceride specimens at HDL-C decision points of 0.35 g/L and 0.60 g/L. Conclusions.—The LN-gen HDL-C assay offers a cost-effective convenient method for meeting the 1998 precision, bias, and total error recommendations of the National Cholesterol Education Program.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3