Interference of Blood Cell Lysis on Routine Coagulation Testing

Author:

Lippi Giuseppe1,Montagnana Martina1,Salvagno Gian Luca1,Guidi Gian Cesare1

Affiliation:

1. From the Istituto di Chimica e Microscopia Clinica, Dipartimento di Scienze Morfologico-Biomediche, Università degli Studi di Verona, Verona, Italy

Abstract

Abstract Context.—Preanalytical factors influencing the reliability of laboratory testing are commonplace. It is traditionally accepted that hemolytic samples are unsuitable for coagulation assays because of the release of hemoglobin, intracellular components, and thromboplastic substances from damaged blood cells. Objective.—To evaluate the influence of blood cell lysis on routine coagulation testing. Design.—Twelve aliquots prepared by serial dilutions of homologous lysated samples collected from 10 different subjects, and displaying a final percentage of lysis ranging from 0% to 9.1%, were tested for prothrombin time, activated partial thromboplastin time, fibrinogen, and dimerized plasmin fragment D. Lysis was achieved by subjecting citrated whole blood to a freeze-thaw cycle. Outcome Measures.—Interference from blood cell lysis on routine coagulation testing. Results.—Statistically significant increases in prothrombin time and dimerized plasmin fragment D were observed in samples containing final lysate concentrations of 0.5% and 2.7% respectively, whereas significant decreases were observed in activated partial thromboplastin time and fibrinogen in samples containing a final lysate concentration of 0.9%. The current analytical quality specifications for desirable bias are ±2.0% for prothrombin time, ±2.3% for activated partial thromboplastin time, and ±4.8% for fibrinogen. Percent variations from the baseline values exceeding the current analytical quality specifications for desirable bias were achieved for lysate concentrations of 0.9% (prothrombin time and activated partial thromboplastin time) and 1.8% (fibrinogen), corresponding to average free plasma hemoglobin concentrations of 1.7 and 3.4 g/L, respectively. Conclusion.—Our results confirm that, although slightly hemolyzed specimens might still be analyzable, a moderate blood cell lysis, as low as 0.9%, influences the reliability of routine coagulation testing. Because the interference in coagulation assays has a wide interindividual bias, we do not recommend lysis correction and we suggest that the most appropriate corrective measure should be free hemoglobin quantification and sample recollection.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

Cited by 34 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3