REDUCTION OF THE INFLUENCE OF DEVIATIONS OF GENERATOR PARAMETERS IN PRECISION QUADRATURE BRIDGES

Author:

,Borchshov P.I.ORCID,Lameko O.L.ORCID, ,Melnyk V.G.ORCID,

Abstract

The article is devoted to solving the problem of attestation of electric capacity standards at industrial frequency. The expediency of using a quadrature bridge of alternating current to determine the parameters of standards of electric capacity at industrial frequency by comparison with the parameters of standards of active resistance was noted. The advantage of using a bridge imbalance indicator with high input impedance is shown, which consists in the possibility of reducing the influence of higher harmonics of the supply voltages. An analysis of the well-known method of reducing of measurement errors caused by the deviation of the generator parameters from the calculated ones was carried out. It is shown that the known method does not provide sufficient compensation for the influence of these errors when the deviations of the generator parameters increase, as well as when the deviations of the bridge from the balance state increase. An iterative algorithm for calculating the measured deviation of the impedance ratio of the compared standards from the nominal value is proposed. Mathematical expressions for calculating the measured quantity are given. Calculations of the components of the measurement error for different values of generator voltage deviations were carried out. Calculations were performed for two variants of generator voltage variation implementation: multiplicative voltage amplitude variation and additive voltage phase variation. The developed iterative correction method allows to reduce the specified errors to the required levels in a small number of iteration steps - in the vast majority of cases, two steps are enough. The application of the method allows obtaining high metrological characteristics with rather large deviations of the voltage ratio of bridge generators, which makes it possible to reduce hardware costs when implementing quadrature alternating current bridges for comparing capacitance and active resistance standards. References 15, figure 1, table 1.

Publisher

National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications)

Reference18 articles.

1. 1. Norms of electrical equipment testing. SOU-Н ЕЕ 20.302:2020. Ministry of Energy and Environmental Protection of Ukraine. PAT Matsionalna energetychna kompania Ukrenergo, 2020. 238 p. (Ukr)

2. 2. Mosty peremennogo toka vysokovoltnye avtomaticheskie SA7100. Rukovodstvo po ekspluatatsii. Kyiv: OOO Oltest, 2020. 132 p. URL: https://oltest.com.ua/wp-content/uploads/2021/08/10-KE-CA7100-ua.pdf (accessed at 05.08.2023). (Rus)

3. 3. Tangens 3М. Avtomaticheskaia ustanovka dlia izmerenia tangensa ugla dielektricheskikh poter izolatsionnogo masla. Kharakteristiki. OOO Kharkovenergopribor. URL: https://kep.ua/ru-ru/tan-delta-tester/tangens-3m#spec (accessed at 05.08.2023). (Rus)

4. 4. State verification schedule for means of measuring of the electrical capacitance and dissipation factor. State Standard of Ukraine 4064-2001: Metrology. Kyiv: Derzhstandart Ukraine, 2002. 11 p. (Ukr)

5. 5. Zakhidprylad. Kataloh vyrobiv. Mira oporu R4016. Tekhnichni kharakterystyky. URL: https://zapadpribor.com/ua/r4016/ (accessed at 05.08.2023). (Ukr)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3