Author:
Shimizu Kyosuke,Osumi Ayumu,Ito Youichi
Abstract
Abstract
A scanning airborne ultrasound source technique was developed to overcome the riskiness of laser ultrasound, which uses an ultrasound source that has a fixed sound wave focusing point and thus requires mechanical motion for sound source scanning. Therefore, the measurement time becomes longer. To solve this problem, we have proposed a method of simultaneously exciting many measurement points in the target using focused ultrasound sources of different frequencies. In this paper, we investigated the visualization of defects in a thin metal plate by the scanning elastic wave source technique using an airborne ultrasound source driven at two frequencies. When the testing was performed using two frequencies, either frequency visualized the defects.
Subject
General Physics and Astronomy,Physics and Astronomy (miscellaneous),General Engineering
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献