Catheter-Related Polymicrobial Bloodstream Infections among Pediatric Bone Marrow Transplant Outpatients—Atlanta, Georgia, 2007

Author:

Wiersma Petra,Schillie Sarah,Keyserling Harry,Watson J. Renee,De Anindya,Banerjee Shailendra N.,Drenzek Cherie L.,Arnold Kathryn E.,Shivers Christina,Kendrick Lea,Ryan Lydia Gonzalez,Jensen Bette,Noble-Wang Judith,Srinivasan Arjun

Abstract

Objective.To identify risk factors for polymicrobial bloodstream infections (BSIs) in pediatric bone marrow transplant (BMT) outpatients attending a newly constructed clinic affiliated with a children's hospital.Methods.All 30 outpatients treated at a new BMT clinic during September 10-21, 2007, were enrolled in a cohort study. The investigation included interviews, medical records review, observations, and bacterial culture and molecular typing of patient and environmental isolates. Data were analyzed using exact conditional logistic regression.Results.Thirteen patients experienced BSIs caused by 16 different, predominantly gram-negative organisms. Presence of a tunneled catheter (odds ratio [OR], 19.9 [95% confidence interval {CI}, 2.4-∞), catheter access (OR, 13.7 [95% CI, 1.8-∞]), and flushing of a catheter with predrawn saline (OR, 12.9 [95% CI, 1.0-766.0]) were independently associated with BSI. The odds of experiencing a BSI increased by a factor of 16.8 with each additional injection of predrawn saline (95% CI, 1.8-827.0). Although no environmental source of pathogens was identified, interviews revealed breaches in recommended infection prevention practice and medication handling. Saline flush solutions were predrawn, and multiple doses were obtained from single-dose preservative-free vials to avoid delays in patient care.Conclusion.We speculate that infection prevention challenges in the new clinic, combined with successive needle punctures of vials, facilitated extrinsic contamination and transmission of healthcare-associated pathogens. We recommend that preservative-free single-use vials not be punctured more than once. Use of single-use prefilled saline syringes might prevent multiuse of single-use saline vials. Storage of saline outside a medication supply system might be advisable. Before opening new clinic facilities, hospitals should consider conducting a mock patient flow exercise to identify infection control challenges.

Publisher

Cambridge University Press (CUP)

Subject

Infectious Diseases,Microbiology (medical),Epidemiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3