Author:
Haiduven Donna J.,McGuire-Wolfe Christine,Applegarth Shawn P.
Abstract
Background.Despite a proliferation of phlebotomy devices with engineered sharps injury protection (ESIP), the impact of various winged device designs on blood splatter occurring during venipuncture procedures has not been explored.Objectives.To evaluate the potential for blood splatter of 6 designs of winged phlebotomy devices.Design.A laboratory-based device evaluation without human subjects, using a simulated patient venous system.Methods.We evaluated 18 winged phlebotomy devices of 6 device designs by Terumo, BD Vacutainer (2 designs), Greiner, Smith Medical, and Kendall (designated A-F, respectively). Scientific filters were positioned around the devices and weighed before and after venipuncture was performed. Visible blood on filters, exam gloves, and devices and measurable blood splatter were the primary units of analysis.Results.The percentages of devices and gloves with visible blood on them and filters with measurable blood splatter ranged from 0% to 20%. There was a statistically significant association between device design and visible blood on devices (P< .0001) and between device design and filters with measurable blood splatter (P< .0001), but not between device design and visible blood on gloves. A wide range of associations were demonstrated between device design and visible blood on gloves or devices and incidence of blood splatter.Conclusions.The results of this evaluation suggest that winged phlebotomy devices with ESIP may produce blood splatter during venipuncture. Reinforcing the importance of eye protection and developing a methodology to assess ocular exposure to blood splatter are major implications for healthcare personnel who use these devices. Future studies should focus on evaluating different designs of intravascular devices (intravenous catheters, other phlebotomy devices) for blood splatter.
Publisher
Cambridge University Press (CUP)
Subject
Infectious Diseases,Microbiology (medical),Epidemiology
Reference21 articles.
1. A Twenty-Five Year Review of Laboratory-Acquired Human Infections at the National Animal Disease Center
2. Safety product evaluation: Six years of experience
3. Risk Of Conjunctival Contamination From Blood Splashes During Surgery At The Kenyatta National Hospital, Nairobi
4. Safety feature evaluation forms. Training for Development of Innovative Control Technologies (TDICT) Project website. http://www.tdict.org/evaluation2.html. Published 1990. Accessed December 21, 2011.
5. Occupational exposure to blood borne pathogens: needle stick and other sharps injuries; final rule 2001. Occupational Safety and Health Administration website. http://www.osha.gov/SLTC/bloodbornepathogens/standards.html. Published 2001. Accessed December 21, 2011.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献