Determination of the Efficacy of Sterile Barrier Systems Against Microbial Challenges During Transport and Storage

Author:

Dunkelberg Hartmut,Schmelz Ulrich

Abstract

Objective.The sterility assurance level of 10−6 is an established standard that defines the quality of sterile products. The aim of the present study was to develop a method that correlated the results from microbial-barrier testing of flexible sterile barrier systems with the estimated microbial challenge that the package encounters during storage and transport.Methods.The effectiveness of microbial-barrier packaging was determined by the use of an exposure chamber test with 20 periodic atmospheric pressure changes of 50 and 70 hPa. Flexible peel pouches were used as sterile barrier systems. The logarithmic reduction value of a sterile barrier system was calculated on the basis of the experimental results and compared with the logarithmic reduction value required for the microbial challenges to maintain sterility during transport and storage.Results.For pouches made of paper and plastic-film material, a logarithmic reduction value of 5.4 was obtained on the basis of 30 of 99 plates becoming nonsterile after being exposed to a 50 hPa difference in periodic atmospheric pressure changes. For pouches made of paper and plastic-film material, a logarithmic reduction value of 5.2 was obtained on the basis of 48 of 100 plates becoming nonsterile after being exposed to a 70 hPa difference in atmospheric pressure. For pouches made of nonwoven and plastic-film material, logarithmic reduction values of 6.38 (ie, 3 of 99 plates became nonsterile after being exposed to a 50 hPa pressure difference) and 6.07 (ie, 3 of the 99 plates became nonsterile after being exposed to a 70 hPa pressure difference) were obtained. Calculating an expected microbial challenge during transport and storage that requires barrier properties corresponding to a logarithmic reduction value of 5.83 and taking the sterility assurance level into account, we found that only the nonwoven pouches fulfilled the European standard EN 556-1.Conclusions.Using the data obtained in a microbial exposure test with a specified flow rate of a bacterial aerosol, we found that the effectiveness of the sterile barrier system against the actual microbial challenge can be examined and evaluated at the sterility assurance level of 10−6.

Publisher

Cambridge University Press (CUP)

Subject

Infectious Diseases,Microbiology (medical),Epidemiology

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3