Cohort Study of the Pathogenesis and Molecular Epidemiology of Catheter-Related Bloodstream Infection in Neonates With Peripherally Inserted Central Venous Catheters

Author:

Garland Jeffery S.,Alex Colleen P.,Sevallius Jackie M.,Murphy Dawn M.,Good Mary J.,Volberding Annette M.,Hofer Leslie L.,Gordon Barbara J.,Maki Dennis G.

Abstract

Objective.To better define the pathogenesis of catheter-related bloodstream infection (BSI) in neonates with peripherally inserted central venous catheters (PICCs) to guide the development of more effective strategies for prevention.Design.Prospective nested cohort study.Setting.Level III neonatal intensive care unit in a community hospital.Methods.During a randomized trial to assess the safety and efficacy of a prophylactic vancomycin-heparin catheter-lock solution for the prevention of catheter-related BSI in neonates with PICCs, we performed cultures of peripheral and catheter-drawn blood samples, and quantitative cultures of catheter hub samples if BSI was suspected clinically. We performed semiquantitative cultures of the catheter tip and the catheter hub and the skin at the insertion site when the catheter was removed. Molecular subtyping by pulsed-field electrophoresis was used to determine the probable pathogenesis of all BSIs due to coagulase-negative staphylococci (CoNS); for BSIs caused by other microorganisms, epidemiologic concordance was based on speciation and antibiograms. Catheter-related BSI was considered extraluminally acquired if concordance was demonstrable solely between isolates recovered from the catheter tip and the blood, independent of concordance with isolates recovered from the insertion site. Catheter-related BSI was considered intraluminally acquired if concordance was demonstrated only between isolates recovered from the catheter hub and the blood. The source of the infection was considered indeterminate if both concordance patterns were present.Results.Nosocomial BSI was identified in 23 of the 82 neonates in the cohort. Fifteen of these infections, 14 of which were caused by CoNS, were considered definite or probable catheter-related BSIs. Catheter-related BSI was intraluminally acquired in 10 (67%) of 15 patients, extraluminally acquired in 3 (20%), and indeterminate in 2 (13%).Conclusions.Most catheter-related BSIs in neonates with PICCs are caused by CoNS and derive from intraluminal contamination. Strategies for prevention of catheter-related BSI directed at this predominant mechanism of infection are most likely to be effective.

Publisher

Cambridge University Press (CUP)

Subject

Infectious Diseases,Microbiology (medical),Epidemiology

Cited by 112 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Health care–associated infections in the nursery;Remington and Klein's Infectious Diseases of the Fetus and Newborn Infant;2025

2. Peripherally inserted central catheter design and material for reducing catheter failure and complications;Cochrane Database of Systematic Reviews;2024-06-28

3. Late-Onset Sepsis;Principles of Neonatology;2024

4. Healthcare-Associated Infections;Avery's Diseases of the Newborn;2024

5. Securement of Umbilical Venous Catheter Using Cyanoacrylate Glue: A Randomized Controlled Trial;The Journal of Pediatrics;2023-09

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3