Author:
Hamill Richard J.,Wright Charles E.,Andres Nita,Koza Maureen A.
Abstract
AbstractAfter identifying a temporal cluster of urinary tract infections in patients who had undergone urodynamic procedures, we examined the techniques within the urodynamic laboratory and retrospectively reviewed charts of all 155 patients tested in the previous six months. The rate of acquired urinary tract infections was 18.7%. Risk factors for infection included undergoing cystometrograms and being subject to the first procedure performed in a day. Technical errors in the performance of the urodynamic studies included failure to completely disassemble the apparatus upon completion of a procedure, failure to use sterile components, and lapses in aseptic technique. Bacteria implicated in the outbreak were isolated from tubing, transducers, and flush solutions. After the institution of appropriate technique, all patients tested in the subsequent six months were followed. The rate of acquired urinary tract infection dropped to 5%. Urodynamic apparatus should be completely disassembled following the completion of a procedure; reassembly using sterile components should occur immediately prior to the next procedure; aseptic technique should be maintained; and patients should undergo routine urine screening before a procedure. Surveillance of urodynamic procedures may reveal correctable flaws in technique.
Publisher
Cambridge University Press (CUP)
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献