Abstract
Abstract
Polarization measurements within 5 to 20 mV of the corrosion potential offer a powerful method for determining corrosion rates. In this paper, known methods for evaluating the corrosion current from polarization data are critically examined. It is noted that calculated currents are generally in error when the anodic and cathodic Tafel slopes are precisely known, due to non-linearity of the polarization curve. A new result is derived, which allows the corrosion current to be calculated without error if the Tafel slopes are known. Diagrams are presented which show the sensitivity of calculated corrosion rates to errors in estimation of the Tafel constants.
Subject
General Materials Science,General Chemical Engineering,General Chemistry
Cited by
31 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献