Author:
PATHANIA R. S.,CHITTY J. A.
Abstract
Abstract
Stress corrosion cracking (SCC) tests were carried out on specimens of Monel 400, Inconel 600, and Sanicro 30 steam generator tubing in solutions containing 10 to 500 g NaOH/kg H2O at 300 C for times up to 600 days. Applied stress and sodium hydroxide concentration had a significant effect on the (SCC) resistance of the three materials.
Subject
General Materials Science,General Chemical Engineering,General Chemistry
Cited by
9 articles.