Testing results of power transformers insulation for the presence of insulation defects, accompanied by the partial discharges occurrence, by means of the acoustic emission method are presented in this article. In particular, the testing of two power transformers with different lifetime was carried out. One transformer was defect-free and one with a willing insulation defect. Based on the testing results, the features of acoustic emission data for power transformers in the presence of partial discharges are found. High sensitivity of acoustic emission method for acoustic wave registration from partial discharges is shown in the article. A method for filtering of noise hits and extraction of hits from partial discharges is proposed. This method is based on excretion of acoustic emission hits from partial discharges out of total number of hits by means of periodicity of their registration, which is synchronized with power supply frequency on the first step. On the next step based on acoustic emission parameters of hits excretion on the previous step, filtration was carried out. The location of the insulation defect which led to the appearance of partial discharges was determined based on the volume location algorithm, by means of acoustic emission method. The insulation defect was confirmed by verification.

Publisher

Izdatel'skii dom Spektr, LLC

Subject

General Medicine

Reference6 articles.

1. Rusov V. A. (2011). Partial discharge measurement in the isolation of high voltage equipment. Ekateriburg: UrGUPS. [in Russian language]

2. Karandaev A. S., Evdokimov S. A., Karandaeva O. I. et al. (2008). Technical condition testing of power transformers by acoustic detection. Vestnik YuUrGU, 26, pp. 26 – 31. [in Russian language]

3. Gun I. G., Salganik V. M., Evdokimov S. A. et al. (2012). Main faults and methods for diagnosing of power transformers in operating mode. Vestnik MGTU im G.I. Nosova, (1), pp. 102 – 105. [in Russian language]

4. Karandaev A. S., Evdokimov S. A., Devyatov D. H. et al. (2012). Diagnostics of power transformers by the method of acoustic location of partial discharges. Vestnik MGTU im G.I. Nosova, (1), pp. 105 – 108. [in Russian language]

5. Sikorski, W., Walczak K. (2012). Power Transformer Diagnostics Based on Acoustic Emission Method In Book Acoustic Emission. Research and Application, Chapter 5, pp. 91 – 116.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3