X-ray vision: the accuracy and repeatability of a technology that allows clinicians to see spinal X-rays superimposed on a person's back

Author:

Aaskov Jacob1,Kawchuk Gregory N.123,Hamaluik Kenton D.2,Boulanger Pierre4,Hartvigsen Jan13ORCID

Affiliation:

1. Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense, Denmark

2. Physical Therapy, University of Alberta, Edmonton, AB, Canada

3. Nordic Institute of Chiropractic and Clinical Biomechanics, University of Southern Denmark, Odense, Denmark

4. Computing Science, University of Alberta, Edmonton, AB, Canada

Abstract

Objective Since the discovery of ionizing radiation, clinicians have evaluated X-ray images separately from the patient. The objective of this study was to investigate the accuracy and repeatability of a new technology which seeks to resolve this historic limitation by projecting anatomically correct X-ray images on to a person’s skin. Methods A total of 13 participants enrolled in the study, each having a pre-existing anteroposterior lumbar X-ray. Each participant’s image was uploaded into the Hololens Mixed reality system which when worn, allowed a single examiner to view a participant’s own X-ray superimposed on the participant’s back. The projected image was topographically corrected using depth information obtained by the Hololens system then aligned via existing anatomic landmarks. Using this superimposed image, vertebral levels were identified and validated against spinous process locations obtained by ultrasound. This process was repeated 1–5 days later. The projection of each vertebra was deemed to be “on-target” if it fell within the known morphological dimensions of the spinous process for that specific vertebral level. Results The projection system created on-target projections with respect to individual vertebral levels 73% of the time with no significant difference seen between testing sessions. The average repeatability for all vertebral levels between testing sessions was 77%. Conclusion These accuracy and repeatability data suggest that the accuracy and repeatability of projecting X-rays directly on to the skin is feasible for identifying underlying anatomy and as such, has potential to place radiological evaluation within the patient context. Future opportunities to improve this procedure will focus on mitigating potential sources of error.

Funder

Department of Physical Therapy, University of Albeta

Publisher

PeerJ

Subject

General Agricultural and Biological Sciences,General Biochemistry, Genetics and Molecular Biology,General Medicine,General Neuroscience

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3