Larger contactor area increases low-frequency vibratory sensitivity in hairy skin

Author:

Schmidt Daniel1,Schlee Guenther2,Germano Andresa M.C.1,Milani Thomas L.1ORCID

Affiliation:

1. Department of Human Locomotion, Faculty of Behavioral and Social Sciences, Institute of Human Movement Science and Health, Chemnitz University of Technology, Chemnitz, Germany

2. Biophysics and Human Performance Lab, W.L. Gore and Associates, Putzbrunn, Germany

Abstract

Background In research, assessing vibratory cutaneous sensitivity is an important research branch to quantify various diseases or to develop devices for pattern recognition. The measured vibration perception thresholds (VPTs), however, are subjective and usually result in a large data variability. This might induce difficulties to detect differences, for example, when comparing different anatomical locations. Hence, a higher ability to detect changes is desirable. Another feature of VPTs is spatial summation, but in the literature it is controversially discussed whether or not this phenomenon is also present in the lower frequency range. For these reasons, the present study aimed to investigate whether an enlarged matrix contactor area (measured at the hairy skin) induces improvements in subjective sensitivity using high and low frequencies, and whether a large contactor area is better able to identify changes of VPTs than a small contactor area of a single contactor. For each frequency, we hypothesized an increased sensitivity for the matrix compared to the single contactor. We also hypothesized that changes can be better-detected between the anatomical locations when using the matrix than the single contactor. Methods Twenty healthy and young participants voluntarily took part in this study. Three anatomical locations at the torso were measured at the middle aspect of the lower back, middle lateral aspect of the upper arm, and the region just below the armpit. At each location, two frequencies (30, 200 Hz) and two contactor conditions (single contactor: 0.48 cm2 , contactor matrix: 9 × 0.48 cm2 = 4.32 cm2) were tested in a randomized order. Results Supporting our hypothesis, we found that improved cutaneous sensitivity after increasing the contactor size occurs not only at high, but also at low frequencies at all anatomical locations. Large contactor sizes resulted in higher sensitivity and in a superior ability to detect changes. The superior behavior of the matrix to exhibit a lower variability could not always be proven. This work may be relevant for future studies aiming to identify changes of VPTs in various patient groups, for example.

Funder

W.L. Gore and Associates GmbH

German Research Foundation/DFG

Chemnitz University of Technology in the funding program Open Access Publishing

Publisher

PeerJ

Subject

General Agricultural and Biological Sciences,General Biochemistry, Genetics and Molecular Biology,General Medicine,General Neuroscience

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3