Affiliation:
1. Department of Human Locomotion, Faculty of Behavioral and Social Sciences, Institute of Human Movement Science and Health, Chemnitz University of Technology, Chemnitz, Germany
2. Biophysics and Human Performance Lab, W.L. Gore and Associates, Putzbrunn, Germany
Abstract
Background
In research, assessing vibratory cutaneous sensitivity is an important research branch to quantify various diseases or to develop devices for pattern recognition. The measured vibration perception thresholds (VPTs), however, are subjective and usually result in a large data variability. This might induce difficulties to detect differences, for example, when comparing different anatomical locations. Hence, a higher ability to detect changes is desirable. Another feature of VPTs is spatial summation, but in the literature it is controversially discussed whether or not this phenomenon is also present in the lower frequency range. For these reasons, the present study aimed to investigate whether an enlarged matrix contactor area (measured at the hairy skin) induces improvements in subjective sensitivity using high and low frequencies, and whether a large contactor area is better able to identify changes of VPTs than a small contactor area of a single contactor. For each frequency, we hypothesized an increased sensitivity for the matrix compared to the single contactor. We also hypothesized that changes can be better-detected between the anatomical locations when using the matrix than the single contactor.
Methods
Twenty healthy and young participants voluntarily took part in this study. Three anatomical locations at the torso were measured at the middle aspect of the lower back, middle lateral aspect of the upper arm, and the region just below the armpit. At each location, two frequencies (30, 200 Hz) and two contactor conditions (single contactor: 0.48 cm2 , contactor matrix: 9 × 0.48 cm2 = 4.32 cm2) were tested in a randomized order.
Results
Supporting our hypothesis, we found that improved cutaneous sensitivity after increasing the contactor size occurs not only at high, but also at low frequencies at all anatomical locations. Large contactor sizes resulted in higher sensitivity and in a superior ability to detect changes. The superior behavior of the matrix to exhibit a lower variability could not always be proven. This work may be relevant for future studies aiming to identify changes of VPTs in various patient groups, for example.
Funder
W.L. Gore and Associates GmbH
German Research Foundation/DFG
Chemnitz University of Technology in the funding program Open Access Publishing
Subject
General Agricultural and Biological Sciences,General Biochemistry, Genetics and Molecular Biology,General Medicine,General Neuroscience
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献