Development of a video camera-type kayak motion capture system to measure water kayaking

Author:

Miyazaki Shigeaki1,Yamako Go2,Kimura Ryo2,Punchihewa Niroshan G.2,Kawaguchi Tsubasa1,Arakawa Hideki1,Chosa Etsuo3

Affiliation:

1. Rehabilitation Unit, University of Miyazaki Hospital, Miyazaki, Japan

2. Department of Mechanical Engineering, Faculty of Engineering, University of Miyazaki, Miyazaki, Japan

3. Department of Orthopaedic Surgery, Faculty of Medicine, University of Miyazaki, Miyazaki, Japan

Abstract

Background In kayaking, trunk motion is one of the important factors that prevent injury and improve performance. Kinematic studies in kayaking have been reported in laboratory settings using paddling simulators and ergometers. However, such studies do not reflect kayaking on water, the actual competitive environment. Therefore, we developed a video camera-type kayak motion capture system (KMCS) wherein action cameras were fixed to a kayak to capture images of markers attached to an athlete’s body. This study aimed to compare the kinematic data between KMCS and an optical motion capture system (OMCS) in kayaking and to determine the accuracy of the KMCS analysis. Methods In a competition, five elite junior female kayak athletes performed kayak paddling under the unloaded condition using a kayak. The kayak was secured using a tri-folding bench and a towel, and twenty strokes were recorded during maximal paddling. One stroke was defined as the period from right catch to left catch, and the first six strokes were used to evaluate the accuracy. Trunk angles (tilting, turning, and rotation) were examined with the simultaneous use of KMCS and OMCS, and the differences between these systems were evaluated. To ensure reliability, intraclass correlation coefficient (ICC; a two-way mixed model for absolute agreement) was calculated for each angle. Furthermore, Bland–Altman analysis was performed to understand the agreement between the two systems. Results Root mean square errors (RMSEs) were 1.42° and 3.94° for turning and rotation, respectively, and mean absolute errors (MAEs) were 1.08° and 3.00° for turning and rotation, respectively. The RMSE and MAE for tilting were 2.43° and 1.76°, respectively, which indicated that the validity was comparable to that of other angles. However, the range of motion in tilting was lower than that in turning and rotation. Bland–Altman analysis showed good agreement in the total range of motion, with mean bias values of −0.84°, −0.07°, and −0.41° for tilting, turning, and rotation, respectively. The ICCs for tilting, turning, and rotation were 0.966, 0.985, and 0.973, respectively, and showed excellent reliability. Conclusions The newly developed KMCS effectively measured the trunk motion with good accuracy in kayaking. In future studies, we intend to use KMCS to measure kayaking on water and collect data for performance improvement and injury prevention.

Publisher

PeerJ

Subject

General Agricultural and Biological Sciences,General Biochemistry, Genetics and Molecular Biology,General Medicine,General Neuroscience

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3