Reliability of sonographic measurements of the ulnar collateral ligament: a multi-rater prospective study

Author:

Felton Shawn D.1,Van Duijn Arie J.2,Cordova Mitchell L.2

Affiliation:

1. Marieb College of Health & Human Services Office of the Dean, Florida Gulf Coast University, Fort Myers, FL, United States of America

2. Department of Rehabilitation Sciences, Florida Gulf Coast University, Fort Myers, FL, United States of America

Abstract

Background The use of sonography is a cost-effective and reliable method to evaluate upper extremity superficial tissue structural integrity and pathology. Establishing the measurement reliability of widely used diagnostic ultrasound evaluation for musculoskeletal assessment is paramount enhance accurate clinical evaluations. The objective of this study was to establish the inter-rater and intra-rater reliability of select ulnar collateral ligament (UCL) thickness measures at two distinct anatomical locations in intercollegiate baseball athletes using ultrasound imaging (USI). Methods This was a prospective cohort study conducted in a university research laboratory and included a total of 17 NCAA Division I baseball athletes (age 20.4 ± 1.43, height = 183.63 cm ± 6.27 cm, mass = 89.28 kg ± 8.24 kg). Two trained clinicians measured UCL mid-substance and apex thickness in the throwing extremity, prospectively, on 5 occasions at 1-month intervals during rest. Intraclass correlation coefficients (ICCs) (model 3,3), associated standard error of measurement, and 95% minimal detectable change in thickness were derived. Results Intrarater reliability estimates for operator 1 were 0.90–0.98 (mid-substance) and 0.91–0.99 (apex). Operator 2’s values were 0.92–0.97 and 0.93–0.99, respectively. The standard error of measurement (SEM) ranged from 0.045–0.071 cm (mid-substance) and 0.023–0.067 cm (apex). The minimal detectable difference (MDD95) was 0.12–0.20 cm (mid-substance) and 0.07–0.19 cm (apex). Interrater reliability was 0.86–0.96 (mid-substance) and 0.79–0.98 (apex); most ICCs were >0.90. Measurement of UCL thickness at two locations demonstrated very good to excellent reliability with high precision. Using this protocol, two evaluators can obtain consistent UCL measurement at two positions. This finding has significant implications for the clinical evaluation of superficial tissue pathology of the same individual by two experienced practitioners.

Publisher

PeerJ

Subject

General Agricultural and Biological Sciences,General Biochemistry, Genetics and Molecular Biology,General Medicine,General Neuroscience

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3