Measurement error using a SeeMaLab structured light 3D scanner against a Microscribe 3D digitizer

Author:

Messer Dolores1,Svendsen Michelle S.2,Galatius Anders3,Olsen Morten T.2,Dahl Vedrana A.1,Conradsen Knut1,Dahl Anders B.1

Affiliation:

1. Department of Applied Mathematics and Computer Science, Technical University of Denmark, Kongens Lyngby, Denmark

2. Globe Institute, University of Copenhagen, Copenhagen, Denmark

3. Department of Bioscience, Aarhus University, Roskilde, Denmark

Abstract

Background Geometric morphometrics is a powerful approach to capture and quantify morphological shape variation. Both 3D digitizer arms and structured light surface scanners are portable, easy to use, and relatively cheap, which makes these two capturing devices obvious choices for geometric morphometrics. While digitizer arms have been the “gold standard”, benefits of having full 3D models are manifold. We assessed the measurement error and investigate bias associated with the use of an open-source, high-resolution structured light scanner called SeeMaLab against the popular Microscribe 3D digitizer arm. Methodology The analyses were based on 22 grey seal (Halichoerus grypus) skulls. 31 fixed anatomical landmarks were annotated both directly using a Microscribe 3D digitizer and on reconstructed 3D digital models created from structured light surface scans. Each skull was scanned twice. Two operators annotated the landmarks, each twice on all the skulls and 3D models, allowing for the investigation of multiple sources of measurement error. We performed multiple Procrustes ANOVAs to compare the two devices in terms of within- and between-operator error, to quantify the measurement error induced by device, to compare between-device error with other sources of variation, and to assess the level of scanning-related error. We investigated the presence of general shape bias due to device and operator. Results Similar precision was obtained with both devices. If landmarks that were identified as less clearly defined and thus harder to place were omitted, the scanner pipeline would achieve higher precision than the digitizer. Between-operator error was biased and seemed to be smaller when using the scanner pipeline. There were systematic differences between devices, which was mainly driven by landmarks less clearly defined. The factors device, operator and landmark replica were all statistically significant and of similar size, but were minor sources of total shape variation, compared to the biological variation among grey seal skulls. The scanning-related error was small compared to all other error sources. Conclusions As the scanner showed precision similar to the digitizer, a scanner should be used if the advantages of obtaining detailed 3D models of a specimen are desired. To obtain high precision, a pre-study should be conducted to identify difficult landmarks. Due to the observed bias, data from different devices and/or operators should not be combined when the expected biological variation is small, without testing the landmarks for repeatability across platforms and operators. For any study necessitating the combination of landmark measurements from different operators, the scanner pipeline will be better suited. The small scanning-related error indicates that by following the same scanning protocol, different operators can be involved in the scanning process without introducing significant error.

Publisher

PeerJ

Subject

General Agricultural and Biological Sciences,General Biochemistry, Genetics and Molecular Biology,General Medicine,General Neuroscience

Reference48 articles.

1. Geomorph: an R package for the collection and analysis of geometric morphometric shape data;Adams;Methods in Ecology and Evolution,2013

2. Geometric morphometrics: ten years of progress following the revolution;Adams;Italian Journal of Zoology,2004

3. The reality of virtual anthropology: comparing digitizer and laser scan data collection methods for the quantitative assessment of the cranium;Algee-Hewitt;American Journal of Physical Anthropology,2016

4. Geographic variation in the skull of the ringed seal, pusa hispida;Amano;Journal of Mammalogy,2002

5. Measurement error in geometric morphometrics: empirical strategies to assess and reduce its impact on measures of shape;Arnqvist;Acta Zoologica Academiae Scientiarum Hungaricae,1998