The validity and reliability of the “My Jump App” for measuring jump height of the elderly

Author:

Cruvinel-Cabral Rejane Maria1ORCID,Oliveira-Silva Iransé2ORCID,Medeiros André Ricarte1ORCID,Claudino João Gustavo3,Jiménez-Reyes Pedro4,Boullosa Daniel A.1ORCID

Affiliation:

1. Physical Education, Catholic University of Brasilia, Águas Claras, Brazil

2. Physical Education Course, University Center of Anápolis - UniEVANGÉLICA, Anápolis, Brazil

3. School of Physical Education and Sport, Laboratory of Biomechanics, University of São Paulo, São Paulo, Brazil

4. Centre for Sport Studies, King Juan Carlos University, Móstoles, Spain

Abstract

Background The ability to jump has been related to muscle strength and power, speed and amplitude of the lower limbs movements, and specifically for the elderly, the vertical jump has been shown to be a good predictor of functional capacity and risk of falling. The use of a mobile application (App) which can measure the vertical jump (i.e., iPhone App My Jump) has recently emerged as a simple, cheap and very practical tool for evaluation of jump ability. However, the validity of this tool for the elderly population has not been tested yet. The elderly usually perform very low jumps and therefore the signal-to-noise ratio may compromise the validity and reliability of this method. Thus, the aim of the current study was to verify the validity and reliability of the iPhone AppMy Jump” for the evaluation of countermovement jump (CMJ) height within an elderly population. Methods After familiarization, 41 participants performed three CMJs assessed via a contact mat and the My Jump App. The intraclass correlation coefficient (ICC) was used to verify the relative reliability, while the coefficient of variation (CV%) and the typical error of measurement (TEM) were used to verify the absolute reliability. Pearson’s correlation coefficient was used to verify the strength of the relationship between methods (i.e., concurrent validity), a Bland–Altman plot to show their agreement, and the Student’s t-test to identify systematic bias between them. For reliability analyses, all jumps were considered (i.e., 123). All jumps (i.e., 123), the average height of each attempt (i.e., 41), and the highest jump, were considered for validity analyses. Results The CMJ height of the highest jump was 10.78 ± 5.23 cm with contact mat, and 10.87 ± 5.32 with My Jump App, with an identified systematic bias of 0.096 cm (P = 0.007). There was a nearly perfect correlation between methods (r = 0.999; P = 0.000, in all cases) with a very good agreement observed (0.3255 to −0.5177 cm, 0.2797 to −0.5594 cm, and 0.3466 to −0.6264 cm, for highest jump height, average jump height, and all jump heights, respectively). The ICC of the My Jump App was 0.948, the TEM was 1.150 cm, and the CV was 10.10%. Conclusion Our results suggest that the My Jump App is a valid and reliable tool compared to the contact mat for evaluating vertical jump performance in the elderly. Therefore, it allows a simple and practical assessment of lower limbs’ power in this population. For the elderly, as well as for other populations with low jumping heights, the highest jump height and the average jump height could be used indistinctly.

Funder

CAPES

CNPq

Publisher

PeerJ

Subject

General Agricultural and Biological Sciences,General Biochemistry, Genetics and Molecular Biology,General Medicine,General Neuroscience

Reference30 articles.

1. Skeletal muscle power measurement in older people: a systematic review of testing protocols and adverse events;Alcazar;Journals of Gerontology: Series A,2017

2. The validity and reliability of an iPhone App for measuring vertical jump performance;Balsalobre-Fernández;Journal of Sports Sciences,2015

3. Statistical methods for assessing agreement between two methods of clinical measurement;Bland;Lancet,1986

4. A comparison of 2 optical timing systems designed to measure flight time and contact time during jumping and hopping;Bosquet;Journal of Strength and Conditioning Research,2009

5. The influence of training background on different rate of force development calculations during countermovement jump;Boullosa;Kinesiology,2018

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3