Establishing an optimized method for the separation of low and high abundance blood plasma proteins

Author:

Yang Henian1,Wang Guijie1,Zhang Tiantian2,Beattie John H.3,Zhou Shaobo1ORCID

Affiliation:

1. School of Life Sciences, Institute of Biomedical and Environmental Sciences and Technology (iBEST), University of Bedfordshire, Luton, Bedfordshire, UK

2. School of Applied Sciences, Bournemouth University, Bournemouth, UK

3. The Rowett Institute, University of Aberdeen, Aberdeen, UK

Abstract

The study tested the efficiency and reproducibility of a method for optimal separation of low and high abundant proteins in blood plasma. Firstly, three methods for the separation and concentration of eluted (E: low abundance), or bound (B: high abundance) proteins were investigated: TCA protein precipitation, the ReadyPrep 2-D cleanup Kit and Vivaspin Turbo 4, 5 kDa ultrafiltration units. Secondly, the efficiency and reproducibility of a Seppro column or a ProteoExtract Albumin/IgG column were assessed by quantification of E and B proteins. Thirdly, the efficiency of two elution buffers, containing either 25% or 10% glycerol for elution of the bound protein, was assessed by measuring the remaining eluted volume and the final protein concentration. Compared to the samples treated with TCA protein precipitation and the ReadyPrep 2-D cleanup Kit, the E and B proteins concentrated by the Vivaspin4, 5 kDa ultrafiltration unit were separated well in both 1-D and 2-D gels. The depletion efficiency of abundant protein in the Seppro column was reduced after 15 cycles of sample processing and regeneration and the average ratio of E/(B + E) × 100% was 37 ± 11(%) with a poor sample reproducibility as shown by a high coefficient of variation (CV = 30%). However, when the ProteoExtract Albumin/IgG column was used, the ratio of E/(B + E) × 100% was 43 ± 3.1% (n = 6) and its CV was 7.1%, showing good reproducibility. Furthermore, the elution buffer containing 10% (w/v) glycerol increased the rate of B protein elution from the ProteoExtract Albumin/IgG column, and an appropriate protein concentration (3.5 µg/µl) for a 2-D gel assay could also be obtained when it was concentrated with Vivaspin Turbo 4, 5 kDa ultrafiltration unit. In conclusion, the ProteoExtract Albumin/IgG column shows good reproducibility of preparation of low and high abundance blood plasma proteins when using the elution buffer containing 10% (w/v) glycerol. The optimized method of preparation of low/high abundance plasma proteins was when plasma was eluted through a ProteoExtract Albumin/IgG removal column, the column was further washed with elution buffer containing 10% glycerol. The first and second elution containing the low and high abundance plasma proteins, respectively, were further concentrated using Vivaspin® Turbo 4, 5 kDa ultrafiltration units for 1 or 2-D gel electrophoresis.

Funder

University of Bedfordshire

Department of Health, Research Project

Scottish Government Rural and Environment Science and Analytical Services Division and a Horizon 2020 RISE grant MILEAGE Project

Publisher

PeerJ

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3