Clinical tool to measure fluorescein patterns in orthokeratology

Author:

López García Rosuero Marina1,Arranz Bombin Alejandro1,Romero Roberto2ORCID,Hornero Roberto2,Martin Raul123

Affiliation:

1. School of Optometry, Universidad de Valladolid, Valladolid, Spain

2. Biomedical Engineering Group, Universidad de Valladolid, Valladolid, Spain

3. IOBA Eye Institute, Universidad de Valladolid, Valladolid, Spain

Abstract

Background Orthokeratology (ortho-k) is an overnight clinical contact lens wear technique to correct myopia and to reduce myopia progression wearing reverse-geometry rigid gas-permeable lenses. The lens fitting procedure in clinical practice usually requires subjective assessment of fluorescein pattern (fluorescein “bull’s eye” pattern). The aim of this study was to develop a novel tool for fluorescein pattern measurements to reduce subjective practitioner dependency, especially in inexperienced practitioners, in ortho-k practice. Methods A new MATLAB customized algorithm to measure the horizontal width of the four main zones of ortho-k fluorescein patterns (central bearing, tear reservoir, mid-peripheral bearing and edge lift) was designed. The algorithm was tested on a small image database consisting of 26 ortho-k fluorescein pattern images of 13 volunteers fitted with reverse geometry lenses (Seefree, Conoptica-Hecht Contactlinsen). The agreement between two independent observers and the ImageJ measurements was determined. Results The new clinical tool provided similar measurements to ImageJ software for the central bearing (4.20 ± 0.74 and 4.27 ± 0.69 mm; P = 0.21), tear reservoir (1.69 ± 0.41 and 1.69 ± 0.45 mm; P = 0.69), mid-peripheral bearing (1.17 ± 0.11 and 1.13 ± 0.10 mm; P < 0.01) and edge lift (0.48 ± 0.06 and 0.48 ± 0.06 mm; P = 0.81) zones. Good agreement between the software (limits of agreement lower than ±0.55 mm) and inter-observer measurements (limits of agreement lower than ±0.66 mm) was found. Conclusions The proposed clinical tool for semiautomatic fluorescein pattern measurements in ortho-k could help to reduce practitioner dependency in fluorescein pattern assessment with future potential to introduce prediction algorithms or artificial intelligence methods in myopia control management.

Publisher

PeerJ

Subject

General Agricultural and Biological Sciences,General Biochemistry, Genetics and Molecular Biology,General Medicine,General Neuroscience

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3