Correlation and agreement of regional cerebral oxygen saturation measured from sensor sites at frontal and temporal areas in adult patients undergoing cardiovascular anesthesia

Author:

Tribuddharat Sirirat,Ngamsaengsirisup Kriangsak,Mahothorn Phatcharakamon,Sathitkarnmanee ThepakornORCID

Abstract

Background The function and viability of the brain depend on adequate oxygen supply. A decrease in cerebral blood supply causing cerebral desaturation may lead to many neurological complications. Direct measurement of regional cerebral oxygen saturation (rScO2) assists in early detection and management. Near-infrared spectroscopy (NIRS) has been introduced for measuring rScO2. A pair of sensors are attached to the right and left forehead. However, there are some situations where the forehead of the patient is not accessible for sensor attachment (e.g., neurosurgery involving the frontal area; a bispectral index (BIS) sensor already attached, or a wound to the forehead); therefore, alternate sites for sensor attachment are required. The temporal area was proposed as an alternate site. The objective of this study was to assess the correlation and agreement of rScO2 measured at the forehead vs. the temporal area. Methods Adult patients undergoing cardiothoracic or vascular surgery were monitored for rScO2 using two pairs of ForeSight sensors. The first pair (A1 and A2) were attached to the right and left forehead, while the second pair (B1 and B2) were attached to the right and left temporal area. The rScO2 values measured from A1 vs. B1 and A2 vs. B2 were assessed for correlation and agreement using the Bland-Altman analysis. Results Data from 19 patients with 14,364 sets of data were analyzed. The data from A1 vs. B1 and A2 vs. B2 showed moderate positive correlation (r = 0.627; P < 0.0001 and r = 0.548; P < 0.0001). The biases of A1 vs. B1 and A2 vs. B2 were −2.3% (95% CI [−2.5 to −2.2]; P < 0.0001) and 0.7% (95% CI [0.6–0.8]; P < 0.0001). The lower and upper limits of agreement of A1 vs. B1 were −17.5% (95% CI [−17.7 to −17.3]) and 12.8% (95% CI [12.6–13.0]). The lower and upper limits of agreement of A2 vs. B2 were −14.6% (95% CI [−14.8 to −14.4]) and 16.0% (95% [CI 15.8–16.3]). Conclusions The rScO2 values measured from sensors at the frontal and temporal areas show a moderate correlation with sufficiently good agreement. The temporal area may be an alternative to the frontal area for cerebral oximetry monitoring.

Funder

Faculty of Medicine, Khon Kaen University

Cardiovascular and Thoracic Surgery Research Group, Khon Kaen University

Publisher

PeerJ

Subject

General Agricultural and Biological Sciences,General Biochemistry, Genetics and Molecular Biology,General Medicine,General Neuroscience

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3